some level of protection from voltage surges will remain, but the Furman’s
clamping voltage rating will be compromised. The unit must be returned to
Furman Sound, or an authorized Furman Service center for repair.
TROUBLESHOOTING
Symptom: No power to the AC outlets.
Possible Cause: Circuit breaker has tripped due to excessive load
Action Needed: Unplug one piece of equipment from the AC-215A and push
the re-set tab into the circuit breaker bezel.
Symptom: No power to the AC outlets, even after the circuit breaker has
been re-set.
Possible Cause: Protection devices are damaged.
Action Needed: Contact the Furman Service Department at 707-763-1010.
Symptom: Extreme Voltage (EVS) indicator lit.
Possible Cause: Input voltage is outside of nominal operation levels. This may
be caused by wiring faults at your location or downed power lines.
Action Needed: Unit will automatically reset and resume operation once the
problem has been corrected.
INSTALLATION
The AC-215A can be conveniently and inconspicuously mounted within an
equipment rack or on the rear panel of your video display, using the included
brackets. Refer to the illustrations below for instructions.