background image

speciFications

Spike Protection Modes:

Line to neutral, zero ground leakage

Spike Clamping Voltage:

188 Vpk @ 3,000 amps, 133 VAC RMS

     (tested to UL-1449 6,000 Vpk @ 3,000 amps) 

Response time:

1 nanosecond

Maximum surge current:

6,500 amps

Voltmeter Accuracy:

  

         

±5V

“In Regulation” Ranges:

AR-15 II:  Provides regulation ±5V in 120V mode from

97 to 137V

Noise attenuation:

10 dB @ 10 kHz 

40 dB @ 100 kHz

100 dB @ 10 MHz

    Linear attenuation curve from 0.05 - 100 ohms line impedance

Shutdown Range:

Above 137 VAC typically

Dimensions:

19 “ W x 11.63” D x 1.75” H

    (48.26 x 29.54 x 4.45 cm)

Weight:

14.5 lbs. (6.58 kg)

Current Rating:

The AR-15 II is capable of 15 amps for input voltages

of 124V (104V in 100V mode) or higher; derate at 113

           mA per volt to a minimum of 12:3A

Three Year Limited Warranty:

The AR-15 is protected by a limited three-year warranty covering defects 
in materials and workmanship. 

Furman sound, LLC. • 1690 Corporate Circle • petaluma, CA 94954-6919 usA

Phone: 707-763-1010 • Fax: 707-763-1310 • Web: www.FurmanSound.com • E-mail: info@furmansound.com

Made in China

12/17/04-C

seRVice

Before returning any equipment for repair, 
please be sure that it is adequately packed 
and cushioned against damage in shipment, 
and that it is insured. we suggest that you 

save the original packaging and use it to 

ship the product for servicing. Also, please 

enclose a note giving your name, address, 

phone number and a description of the 

problem.

note: All equipment being returned for re-

pair must have a Return Authorization (RA) 

number. to get an RA number, please call 

the Furman service department, (707) 763-

1010, ext. 2370 or 2377, between 8 a.m. 

and 5 p.m. U.S. Pacific Time, or fax to (707) 

763-1310. please display your RA number 

prominently on the front of all packages.

Summary of Contents for AR-15

Page 1: ...AC Line Voltage Regulator and power conditioner AR 1 5 Voltage Regulators ...

Page 2: ...ur Furman AR 15 please be sure to read this manual carefully WARNING To reduce the risk of electrical shock do not expose this equipment to rain or moisture Dangerous high voltages are present inside the enclosure Do not remove the cov ers There are no user serviceable parts inside Refer servicing to qualified personnel only The lightning flash with arrowhead symbol within an equilateral triangle ...

Page 3: ... MIDI programs or other data or in extreme cases permanent damage They accept input voltages over a wide AC voltage range and convert them to a steady stable output at the desired standard voltage plus or minus five volts Voltages ap proximately 10 beyond that range may be converted to usable levels depending on the requirements of the equipment This stable voltage protects equipment and allows op...

Page 4: ...ED will light if the input voltage is above the extreme voltage cutoff and power will not be applied to the unit s outlets If the unit has been operating with an acceptable input voltage and subsequently that voltage exceeds 145 150V it will shut off power to the outlet and the Extreme Voltage LED will light NOTE If the mains power is above the high cutoff voltage and has caused the unit to remove...

Page 5: ...the Voltage Regulator output Installation Because of their toroidal transformer design Furman Voltage Regulators may be posi tioned near most other equipment without fear that the other equipment will be disrupted by leakage of a strong 50 60 Hz magnetic field Nevertheless suggested rack locations would be either at the top or bottom As with any rackmount equipment be sure to use 10 32 machine scr...

Page 6: ...s a device which through use of a transformer corrects the voltage deviation by stepping it up or down so that it is as close as possible to the nominal level SPIKE A pulse of energy on the power line Spikes can have voltages as high as 6000 volts Though they are usually of very short du ration the energy they contain can be consid erable enough to damage sensitive solid state components in audio ...

Page 7: ...NTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR POSE Manufacturer does not warrant against damages or defects arising out of improper or abnormal use of handling of the Product against defects or damages arising from im proper installation against defects in products or components not manufactured by Manufac turer or against damages resulting from such non Manufacturer made products or c...

Page 8: ...nty The AR 15 is protected by a limited three year warranty covering defects in materials and workmanship Furman Sound LLC 1690 Corporate Circle Petaluma CA 94954 6919 USA Phone 707 763 1010 Fax 707 763 1310 Web www FurmanSound com E mail info furmansound com Made in China 12 17 04 C Service Before returning any equipment for repair please be sure that it is adequately packed and cushioned against...