specIFIcatIons

Spike Protection Modes:

Line to neutral, zero ground leakage

Spike Clamping Voltage:

188 Vpk @ 3,000 amps, 133 VAC RMS

(tested to UL-1449 6,000 Vpk @ 3,000 amps)

Response time:

1 nanosecond

Maximum surge current:

6,500 amps

Voltmeter Accuracy:

  

         

±1V

Noise attenuation:

10 dB @ 10 kHz 

40 dB @ 100 kHz

100 dB @ 10 MHz
Linear attenuation curve from 0.05 - 100 ohms line impedance

“In Regulation” Ranges:
        

Regulates to120V ±5V from 97 to 137V

Shutdown Range:

Above 137 VAC typically

Dimensions:

19 “ W x 17.125” D x 3.5” H

Weight:

36 lbs

Current Rating:

20 amperes for input voltages of 104/124* or higher  
*Derate at .15 A per volt to a minimum of 16.5A

Three Year Limited Warranty:

The AR-20 II is protected by a limited three-year warranty covering defects 
in materials and workmanship. 

Furman Sound, LLC. • 1690 Corporate Circle • Petaluma, CA 94954-6919 USA

Phone: 707-763-1010 • Fax: 707-763-1310 • Web: www.FurmanSound.com • E-mail: info@furmansound.com

engineered in the usA

Made in China

2/23/06 - D

seRVIce

Before returning any equipment for repair, 
please be sure that it is adequately packed 
and cushioned against damage in shipment, 

and that it is insured. we suggest that you 

save the original packaging and use it to 

ship the product for servicing. Also, please 

enclose a note giving your name, address, 

phone number and a description of the 

problem.

NOTE: All equipment being returned for repair 

must have a Return Authorization (RA) Num-

ber. To get an RA Number, please call the Fur-

man Service Department, (707) 763-1010, ext. 

2370 or 2377, between 8 a.m. and 5 p.m. U.S. 

Pacific Time, or fax to (707) 763-1310. Please 

display your RA Number prominently on the 

front of all packages.

Summary of Contents for AR-20 II

Page 1: ...AC Line Voltage Regulator and power conditioner AR 20 II Voltage Regulators...

Page 2: ...ck do not expose this equipment to rain or moisture Dangerous high voltages are present inside the enclosure Do not remove the cov ers There are no user serviceable parts inside Refer servicing to qua...

Page 3: ...e and convert them to a steady stable output at the desired standard voltage plus or minus five volts Voltages ap proximately 10 beyond that range may be converted to usable levels depending on the re...

Page 4: ...ot be applied to the unit s outlets If the unit has been operating with an acceptable input voltage and subsequently that voltage exceeds 145 150V it will shut off power to the outlet and the Extreme...

Page 5: ...ulator output Installation Because of their toroidal transformer design Furman Voltage Regulators may be posi tioned near most other equipment without fear that the other equipment will be disrupted b...

Page 6: ...tor is a device which through use of a transformer corrects the voltage deviation by stepping it up or down so that it is as close as possible to the nominal level SPIKE A pulse of energy on the power...

Page 7: ...ANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR POSE Manufacturer does not warrant against damages or defects arising out of improper or abnormal use of handling of the Product against defe...

Page 8: ...covering defects in materials and workmanship Furman Sound LLC 1690 Corporate Circle Petaluma CA 94954 6919 USA Phone 707 763 1010 Fax 707 763 1310 Web www FurmanSound com E mail info furmansound com...

Reviews: