19
FR
A
N
Ç
A
IS
EN
G
LIS
H
ES
P
A
Ñ
O
L
SPECIFICATIONS
INPUT
Voltage:
90 – 140 Vac
Frequency:
57 – 63 Hz
AC POWER
Surge Protection:
Non-sacrificial
SMP (Series Multi-Stage Protection)
Current Rating:
12 A maximum (7.5 A maximum battery load recommended)
Overvoltage Shutoff, fast rise:
150 ± 5 V
Overvoltage Shutoff, slow rise:
140 ± 5 V
Noise Attenuation:
10 dB @ 10kHz, 40 dB @ 100 kHz, 50 dB @ 500kHz
Linear Attenuation Curve:
From 0.05 - 100 Ohms line impedance
Automatic Voltage Regulation,
Sensitive Mode Capture Range:
98 – 135 Vac
Automatic Voltage Regulation,
Sensitive Mode Output Range:
120 ± 5%
Automatic Voltage Regulation,
Standard Mode Capture Range:
93 – 145 Vac
Automatic Voltage Regulation,
Standard Mode Output Range:
120 ± 10%
UPS OUTPUT
Voltage:
120 ± 5 V True Sine Wave
Frequency:
60 Hz ± 1%
UPS Output Capacity:
1500VA, 900W @ 0.6pf
UPS Backup Time:
12 minutes at full load, 32 minutes at half load
Transfer Time:
< 4ms
Temperature Rating:
Units are considered acceptable for use in a
maximum ambient of 40°C (or “0 ~ 40°C” for ambient operation)
Product:
3.5” H x 19.2” L x 17” W
Weight:
72 lbs