Re-syncing Multiple Sequencers

There can be unique situations where multiple sequencers fall out of 
sync. For example, loss of sync can occur when a branch circuit experi-
ences an overload or high voltage and triggers an EVS shutdown of one 
or more units. If you are using a rack mounted Contractor unit equipped 
with SmartSequencing, you can re-establish sync by pressing and holding 
the Start Sequence pushbutton on the Primary Unit for several seconds.  
Sync can also be re-established by rotating the key on the primary unit 
from the REMOTE to the OFF position and then back to REMOTE.  When 
pressing and holding the pushbutton on dedicated SmartSequencing 
units, the Primary Unit commands the Secondary Units to “Go Home” 
and all units will sequence down in reverse order. Once the chain of 
sequencers has cycled off, the sequencers can be sequenced on again 
by pressing the START SEQUENCE button or turning the key switch to the 
ON position.

Legacy connected sequencers can also be re-synced if the sequencers 
are operating Momentary Mode.  The units will resync can be accom-
plished by pressing and holding the Start Sequence pushbutton.  Unlike 
the SmartSequencing chains, units will cycle down, yet may not cycle 
down in hierarchical order.  It is advised that all sound sources be muted 
before a re-sync action is initiated. Once the re-sync is initiated, unit will 
cycle down and return to an off state.  A sequence can now be “ramped 
up” in order.

SPECIFICATIONS

Maximum AC Current Rating:

   • CN-15MP - 15 Amps, 120 VAC (Thermal circuit breaker) 
   • CN-20MP - 20 Amps, 120 VAC (No circuit breaker))

AC Cord: 

   • 3/14 AWG, 10 feet, black, fixed, NEMA 5-15P plug

AC Receptacles:

   •  AC Outlets: 2 Switched NEMA 5-15R (1 duplex)
   

Surge/Under-Overvoltage Protection:

   • AC Undervoltage Protection: EVS, 77VAC+/-3VAC
   • AC Overvoltage Protection: EVS, /-5VAC
   • AC EVS Protection Activate/Deactivate Modes: ON or OFF DIP 9 (configurable)

Operating Temperature Range:

 

   • 5C (40F) to 40C (105F) degrees

Humidity Range:

 

   • <90% rH (Relative Humidity)

User Interface:

   • Thermal Circuit Breaker: Bottom panel, pushbutton (CN-15MP only)    
   • Front panel diagnostic indicators: Primary link, Secondary link, Power, Extreme Voltage 
   • Side Panel DIP Switches: Hidden by security cover, 1 Minute Delay, 
      2 Minute Delay, 4 Minute Delay, Force Off NO/NC, 12V Mode ON/OFF, GND Mode On,  
      Momentary/Maintained, Primary/Secondary, EVS ON/OFF
  • Potentiometer: Side panel, time calibration hidden by security cover, fine tune delay    
       adjust

Control/Status/Triggering (Front Panel):

   • Remote Terminal: +5-30VDC IN, 12VDC (12mA) OUT
   • SmartSequencing: Phoenix type 4-Pin Connector, with Screw Terminals, Primary & 
      Secondary Links (Current Loop - 1000’ maximum) 
   • Remote Terminal: Phoenix type 5-Pin Connector with Screw Terminals; 
      +12V, STAT, REM, GND, DLY OUT (Class 2 Wiring)
   • Force Off: Phoenix type 2-Pin Connector with Screw Terminals, (Class 2 Wiring)            

Power Consumption (No Load): 10 Watts
        
Safety Agency:  NRTL-C       CSA/NRTL Compliant: 

Specifications subject to change due to product upgrades and improvements.

Full Warranty and Policy information available at 

www.furmancontractor.com

15 YEAR LIMITED PRODUCT WARRANTY* 

Furman warrants to the original purchaser of this product for a 

period of fifteen (15) years from the date of purchase, that the 

unit shall be free of defects in design, material or workman-

ship, and Furman will repair or replace any defective unit.

CAUTION! WARRANTY LIMITATION FOR INTERNET PURCHASERS

Furman products purchased through the Internet do not carry a valid 
Product Warranty unless purchased from an Authorized Furman 
Internet Dealer and the original factory serial numbers are intact 
(they must not have been removed, defaced or replaced in any way). 
Purchasing from an Authorized Furman Internet Dealer insures that 
the product was intended for consumer use, has passed all quality 
inspections and is safe. Buying through auction sites or unauthorized 
dealers may result in the purchase of salvaged, failed and/or products 
not intended for use in the US. In addition, Authorized Furman Internet 
dealers have demonstrated sufficient expertise to insure warranty 
compliant installations.

For a list of Authorized Furman Internet Dealers 

go to www.furmansound.com

Summary of Contents for CONTRACTOR MINIPORT CN-15MP

Page 1: ...P A S S C U S CN 20MP CN 15MP Contractor Grade Power Management with SmartSequencing Technology Features SmartSequencing technology allows large complex A V systems to be safely power cycled on and o...

Page 2: ...g power to the amplifiers When shutting down the A V system a sequencer will turn off the system in the reverse order hence the amps will be turned off first and then the signal processing equipment w...

Page 3: ...urrent loop In situations where power sequencing is critical or more than one AC electrical circuit is utilized wiring Furman SmartSequencing products in series is simple fast and reliable EVS EXTREME...

Page 4: ...the manufacturer 10 Refer all servicing to qualified personnel Servicing is required when the unit has been damaged in any way or fails to operate 11 WARNING Do not use power cord as the main power d...

Page 5: ...ON 12V OFF GND ON MOM MNT PRI SEC EVS AUTO MANUAL 6 7 8 9 1 2 3 4 5 6 7 8 9 ON FOR REFERENCE ONLY ABBREVIATED DESCRIPTIONS AS SHOWN ON THE PRODUCT NOT FOR SETTING S INSTRUCTIONS EXAMPLE 1 DIAGRAM SMA...

Page 6: ...A EXAMPLE 3 DIAGRAM LARGE LEGACY UPGRADE EXAMPLE 4 DIAGRAM LARGE SET UP PRIMARY CONTROLLED VIA RS 232 P P S S CN 1800S 12 STAT REM GND UNIT 3 SECONDARY INTERFACE NO NC C FORCE OFF FORCE OFF P P S S CN...

Page 7: ...o the Secondary IN of the next downstream sequencer A Furman SmartSequencing chain communicates using a bucket brigade technique A Primary Unit communicates to the first Secondary Unit downstream by s...

Page 8: ...control system is either inaccessible or commanding the outputs to an OFF state It should be noted that the FORCE OFF and EVS conditions have priority over the BYPASS switch and if either of these co...

Page 9: ...will be triggered when the short between the two FORCE OFF pins is removed If a FORCE OFF is triggered the FORCE OFF message will be propagated to all SmartLink connected devices The power to all of t...

Page 10: ...ate as a Secondary Sequencer 8 1M 1 2 3 4 5 2M 4M N O N C 12V ON 12V OFF GND ON MOM MNT PRI SEC EVS AUTO MANUAL 6 7 8 9 1 2 3 4 5 6 7 8 9 9 1M 1 2 3 4 5 2M 4M N O N C 12V ON 12V OFF GND ON MOM MNT PRI...

Page 11: ...utlet If power is provided to the outlet the LED will illuminate green If the Miniport is operating under safe power conditions and no utility fault conditions exist the POWER LED will remain steadily...

Page 12: ...ect the signal processing equipment to the Mini ports near the beginning of the chain and the Amplifiers to the sequenc ers nearest the end of the chain This will ensure that the power to the signal p...

Page 13: ...lative Humidity User Interface Thermal Circuit Breaker Bottom panel pushbutton CN 15MP only Front panel diagnostic indicators Primary link Secondary link Power Extreme Voltage Side Panel DIP Switches...

Reviews: