ELITE 15 DM OWNER’S MANUAL
construction, design, or componentry to wear
over the life time of the product, and there is
no power draw from your electric service meter
aside from the LED power indicator, and relay
circuits. For this reason the Elite-15 DM may
be left with its power engaged permanently at a
cost of pennies per month.
AC Transient Voltage Surge Suppression
and Extreme Voltage Shutdown
Extreme Voltage Shutdown Indicator:
This LED is normally off. It monitors AC wiring
faults – for example, accidental connection
to an open neutral from a 208 or 240VAC
feed (this is a common occurrence if the 15
Amp outlet source is not a dedicated line, but
instead has been wired with a daisy-chained
neutral from a homes breaker box). The Series
Multi-Stage Protection Plus (SMP+) circuit
senses voltages that are so high that operation
would be impossible and shuts the power
down before damage can occur. Upon initially
applying power to these units, the Extreme
Voltage indicator LED will light if the input
voltage is above the extreme voltage cutoff,
and power will not be applied to the unit’s
outlets. If the unit has been operating with an
acceptable input voltage and subsequently that
voltage exceeds 137V, it will shut off power to
the outlet and the Extreme Voltage LED will
light.
Protection OK Indicator:
Although the Furman SMP+ circuit assures
virtually maintenance free protection from
transient voltage spikes and surges, nature
has a way of occasionally creating electrical
forces that are beyond the capabilities of any
Transient Voltage Surge Suppression device
to absorb without some degree of damage. In
the rare instance that this occurs, the blue
LED located in the center of the front panel
will dim, even though AC power is present at
the unit’s outputs. If this happens, some level
of protection from voltage surges will remain,
but the Furman’s clamping voltage rating will
be compromised. The unit must be returned
to Furman Sound, or an authorized Furman
Service center for repair.
NOTE: If the mains power is above the high
cutoff voltage and has caused the unit to
remove power from its outlets, it cannot restore
power without the operator manually turning
the unit off, then on again. Avoid turning the
unit back on, without fi rst checking the source
of the problem, and perhaps changing the AC
source.
Telco – Satellite – Cable Transient Voltage
Surge Suppressors
The Elite-15 DM features transient voltage
surge suppression for both standard telephone
lines, as well as cable or satellite lines utilizing
standard coaxial connectors. As these surge
suppressors are in-line, they will require an
additional cable to connect from their output to
the control device requiring protection.
All in-line surge suppressors feature
our exclusive ground contamination free
technology. This aids in eliminating audio
buzzing, and the video hum-bars that can
result from typical in-line suppressors. Further,
our cable and satellite suppressors are TIVO
friendly as well as HD-Digital Television
ready. Both DC carrier signals as well as high
bandwidth signals can pass through our circuit.
In fact the bandwidth is less than 0.1dB loss at
1GHz!
4
Summary of Contents for Elite15DM
Page 1: ...ELITE 15 DM OWNER S MANUAL...