LIST OF ALL COMMANDS AND QUERIES
Send Query to UPS:
?HELP<CR>
Action:
List of all commands and queries will be displayed
Response:
!ALL_ON<CR>
!ALL_OFF<CR>
!SWITCH<CR>
!SET_BATTHRESH<CR>
!SET_BUZZER<CR>
!SET_AVR<CR>
!SET_FEEDBACK<CR>
!SET_LINEFEED<CR>
!RESET_ALL<CR>
!SET_BRIGHT<CR>
!SET_SCROLLMODE<CR>
!SET_SLEEPMODE<CR>
?ID<CR>
?OUTLETSTAT<CR>
?POWERSTAT<CR>
?VOLTAGE<CR>
?LOADSTAT<CR>
?BATTERYSTAT<CR>
?LIST_CONFIG<CR>
?HELP<CR>
RESPONSES & MESSAGES
OUTLET STATUS CHANGE
CONDITION
RESPONSE
Outlet Bank 1 changes state
$BANK1 = status<CR>
Outlet Bank 2 changes state
$BANK2 = status<CR>
status = {ON, OFF}
POWER BUTTON STATUS CHANGE
CONDITION
RESPONSE
Power Button changes ON/OFF status
$BUTTON = status<CR>
status = {ON, OFF}
POWER FAULT STATUS CHANGE
CONDITION
RESPONSE
Overvoltage State
$PWR = OVERVOLTAGE<CR>
Undervoltage State
$PWR = UNDERVOLTAGE<CR>
Lost Power State
$PWR = LOST POWER<CR>
Test Mode
$PWR = TEST<CR>
Recovery Mode
$PWR = RECOVERY<CR>
Normal Operation Mode $PWR = NORMAL<CR>
Low Battery
$LOWBAT<CR>
AVR Stage
$AVRSTATE = state<CR>
state = {BOOST, BUCK}
Remaining Backup Time $TIME = xxx<CR>
xxx = backup time
Battery State
$BATTSTATE = xxx<CR>
xxx = {CHARGE, DISCHARGE, FULL}