background image

IT-R

efeRence

 20

i

 O

wneR

s

 M

anual

IT-Reference 20i Features

     •  Discrete Symmetrical Power cancels hum inducing noise from audio and video
     •  Four discrete dual screen power banks eliminate inter-component interference and noise
     •  Power Factor Technology provides current on demand for power-starved amplifiers
     •  Linear AC filtering for unequaled audio / video clarity 
     •  Virtually maintenance-free AC surge suppression
     •  Three high definition ready bidirectional coaxial surge suppression modules 
     •  Detachable telco surge suppression module

Introduction

For over 33 years, Furman has pioneered the development of AC power products for the most demanding audio, video, and 
broadcast professionals.  Though the need for pristine AC power is nothing new, the IT-Reference 20i’s technology and its unique 
implementation are revolutionary and without peer. 

The extreme AC demands encountered in the professional audio/video arena have required technological developments far in 
excess of typical home theater/audiophile power products.  In studios, live audio/video, and broadcast facilities, breakdown is 
unacceptable.  Equipment failure or poor performance is costly.  The same is true of today’s home theater.  Our solution-based 
technology, extensive engineering expertise, and robust build quality have answered the challenge of today’s corrupted power 
lines, and led to the creation of our flagship power conditioner, the IT-Reference 20i.

Today’s AC lines are plagued with ever increasing noise.  When AC noise couples into your system’s critical components, it masks 
low level signals and cripples performance. This low level content is critical because it relays the crucial harmonics and ambience 
in audio, and depth and clarity in video reproduction.  With the IT-Reference 20i’s exclusive Discrete Symmetrical Power, video 
screens, projectors, CD or DVD players, pre-amplifiers, and scalers are fed linearly-filtered ultra-low-noise symmetrical power.  
This dramatically reduces AC noise, ensuring peak operation of your critical components.  For the first time, you will see and hear 
your theater or audio system as it should be...uncompromised.   

Further, our Discrete Symmetrical Power features total isolation between four discrete AC outlet banks.  This positively breaks 
noise-inducing ground loops, hum bars, and power supply backwash between interconnected equipment, all without 
compromising electrical safety.  This enables a plasma screen to function without AC ground contamination from a compact disc 
player, or a preamplifier-processor to function free of performance-degrading digital noise from a satellite receiver. 

The IT-Reference 20i also employs our unique Power Factor Technology circuit. This means low-level analog, digital, and video 
components are not modulated or distorted via the power amplifier’s extreme AC current demands.  Further, the power amplifier 
sees a highly filtered, extremely low-impedance supply of AC power.  The IT-Reference 20i, in fact, has in excess of 9 Amps of 
continuous current reserve (over 80 amps pk. charge) for the most extreme peak power demands. This technology enables 
power amplifiers and powered subwoofers to work at peak efficiency and reach levels of performance previously unattainable. 

No longer will your amplifier’s performance be at the mercy of your home’s incoming AC power or inferior AC protection/filtering 
devices.  The net effect is as if your power amplifier doubled in power and improved immeasurably in quality.  

When employing the IT-Reference 20i you will immediately notice far clearer, stunningly focused sound and visual images from 
your system. Video presentation will be crisp and colors true with greater gray and black scale definition, as well as noticeably 
improved depth and clarity. Sonic transients will be startlingly fast with bass fundamentals that shake foundations with 
their weight and visceral impact. Mid and high frequencies will bloom with sweet, non-glaring ease while imaging improves 
dramatically, all the while remaining true to your system’s inherent virtues.

Summary of Contents for IT-REFERENCE 20i

Page 1: ...MMETRICAL POWER CONDITIONER CONDITIONNEUR D ALIMENTATION SYM TRIQUE DISCRET ACONDICIONADOR DE POTENCIA SIMETRICA Y DISCRETA OWNER S MANUAL GUIDE DE L UTILISATEUR MANUAL DEL PROPIETARIO DISCRETE SYMMET...

Page 2: ......

Page 3: ...i Guide De L Utilisateur IT REFERENCE 20i DISCRETE SYMMETRICAL POWER CONDITIONER CONDITIONNEUR D ALIMENTATION SYM TRIQUE DISCRET ACONDICIONADOR DE POTENCIA SIMETRICA Y DISCRETA OWNER S MANUAL GUIDE DE...

Page 4: ...ymmetrical power This dramatically reduces AC noise ensuring peak operation of your critical components For the first time you will see and hear your theater or audio system as it should be uncompromi...

Page 5: ...ence 20i has been dropped or the enclosure damaged Power Source The power source to which the IT Reference 20i is connected should be adequate for use at 20 Amps Though the system may function with a...

Page 6: ...mponent AC cords to the IT Reference 20i s four Discrete power banks We recommend separating digital processors DVD s and CD players from pre amplifiers tuners and tape machines Further video monitors...

Page 7: ...symmetrical AC power output whereby both the neutral and positive leads of the AC cable run at 60 Volts AC in opposing polarity referenced to ground 0 Volts AC This is but one of the IT Reference 20i...

Page 8: ...an additional cable to connect from their output to the control device requiring protection All in line surge suppressors feature our exclusive ground contamination free technology This aids in elimin...

Page 9: ...urman determines that the damage did not result from the Occurrence or that no Occurrence in fact took place or Furman determines that the connected equipment was not used under normal operating condi...

Page 10: ...ing power amplifiers to work more efficiently Linear Noise Attenuation Transverse Differential Mode 20 dB from 1Khz 2 kHz 40 dB from 2Khz 100 kHz 80 dB from 100 kHz 1GHz Linear attenuation curve from...

Page 11: ...11 FRAN AIS ENGLISH...

Page 12: ...itiques de votre syst me il masque les signaux de faible intensit et d t riore le rendement Ces signaux sont importants car ils transmettent les harmoniques essentielles et l ambiance au niveau du son...

Page 13: ...opri t originaux en plus de nous permettre de vous informer des mises niveau ou de vous transmettre d autres renseignements importants Information sur la s curit et avertissements Veuillez lire et app...

Page 14: ...re si vous faites face au panneau arri re Ensuite la fiche Edison m le doit tre reli e un prise appropri e se reporter aux recommandations susmentionn es sur le courant nominal Ce cordon c a v hicule...

Page 15: ...ndes de courant de cr te sont beaucoup plus importantes l appel de puissance total maximum en continu peut tre limit selon une plage variant entre 1 500 et 2 100 W par unit IT Reference 20i utilis e L...

Page 16: ...nce 20i ou du syst me d alimentation d un composant connect Dans ce cas nous devons prioriser la s curit La solution est notre disjoncteur de fuite la terre GFCI Ground Fault Circuit Interrupter Le GF...

Page 17: ...est de moins de 0 1 dB 1 GHz Pour brancher vos c bles ces dispositifs de protection en ligne il vous suffit de suivre les indications in et out indiqu es c t des connecteurs Cable et ou Satellite REMA...

Page 18: ...utilis sous des conditions normales d utilisation ou selon les instructions propos es par le Fabricant de l quipement connect Tous les limiteurs de surtension de Furman doivent tre reli s directement...

Page 19: ...dance d entr e c a de mani re en maximiser le fonctionnement Att nuation du bruit Mode transversal diff rentiel 20 dB de 1 kHz 2 kHz 40 dB de 2 kHz 100 kHz 80 dB de 100 kHz 1 GHz courbe d att nuation...

Page 20: ...Notes...

Page 21: ......

Page 22: ...Notes...

Page 23: ......

Page 24: ...1690 Corporate Circle Petaluma California USA 94954 Phone 877 486 4738 Fax 707 763 1310 www FurmanSound com ITREF20iM_Rev2a...

Reviews: