background image

IT-R

efeRence

 20

i

 O

wneR

s

 M

anual

For rack mounting that will be transported, rear rack mounting is recommended due to the high mass of the IT-Reference 20i.  
These rear rack kits are not necessary for a stationary installation.  They are available from your Furman dealer as an optional 
accessory.  The rear rack mount kit model number is: 

 RRM-3 REF

.

Connection

AC Cable Routing

Once the IT-Reference 20i is placed, its AC cord’s female end must be plugged into the male IEC connector located on the lower 
left hand side of the rear panel (when facing the rear panel).  Next the male Edison plug must be connected to an appropriate 
socket (see current rating recommendation above).  This AC cord will carry substantial unbalanced AC current, so it should be 
dressed away from critical signal-carrying cables, or at the very least, cross them at a 90 degree angle.  The same is true of the 
power amplifier AC cords when plugged into the IT-Reference 20i’s “High Current - Amplifier Power” AC filtered outputs.  All other 
components plugged into “Discrete Symmetrical Power” outlets (A) through (D) have symmetrical AC current and will radiate 
virtually no field; as a result of this technology, their placement is not critical.  

Connecting Components to the Symmetrical Power Banks

The IT-Reference 20i’s “Symmetrical Power Outlets” should be employed for all components other than receivers with power 
amplification, power amplifiers, powered subwoofers, or powered loudspeakers.  Each “Discrete” bank (A) through (D) contains 
two parallel outputs that are symmetrically balanced, filtered, and totally isolated from adjacent output banks or the (4) “High 
Current - Amplifier Power” outlets. It should be noted that as each AC bank’s outlets are in parallel, component power supply 
noise 

could

 potentially “back-wash” between these units.  

For this reason it is recommended that systems with minimal components (four units or less, excluding the power amplifiers) 
utilize one “Discrete bank” per component.  This will maximize performance by eliminating inter-component AC noise 
contamination entirely!  For systems utilizing more componentry, high performance will still be achieved with careful routing of 
component AC cords to the IT-Reference 20i’s four “Discrete” power banks.  We recommend separating digital processors, DVD’s, 
and CD players from pre-amplifiers, tuners, and tape machines. Further, video monitors and scalers should ideally be separated 
from audio components.  

Connecting Components to the High Current Power Amplifier Banks

Many audiophile and premium home theater systems will have combined continuous current demands far below 20 Amps.  It is 
rare, in fact, for large power amplifiers to draw more than 4 Amps continuously.  

For superior performance, it is vital that an AC filter possess extraordinarily low impedance, and have the capability to pass peak 
current demands far in excess of the RMS (continuous) current rating.  The IT-Reference 20i was designed to more than meet this 
demand.  Additionally, our Power Factor Technology circuitry effectively creates a current reserve in excess of 80 amps peak up-
charge that is cleaner and more efficient than a dedicated line from your local power station.  This feature eliminates any concern 
with the current compression that can result from typical power conditioners.  In fact, Furman’s Power Factor Technology 
circuitry provides lower AC impedance with current on demand which benefits any power amplifier’s performance dramatically.

Note about Power Factor Technology and Current Consumption

When Power Factor Technology is employed (transient or RMS), even the most sophisticated circuit breakers will perceive an 
increased current load. Though the IT-Reference 20i was designed for steady 20 Amp operation, and peak current demands 
many times that, the maximum total continuous current draw may be limited to a range between 1500 - 2100 Watts per IT-
Reference 20i employed.  

The RMS current available before the circuit breaker trips varies greatly due to what is referred to as a vector load.  Simply put, 
the type of power supplies or electronic circuits connected to the IT-Reference 20i will have an effect on its circuit breakers 
perceived current load, and therefore, when it will trip.  Though the benefits of Power Factor Technology far outweigh the small 
reduction in continuous current draw, this must be accounted for when constructing a large system with high current demands.  

The total continuous current draw of most electronic components is typically listed in Watts by their AC input cord or AC 

Summary of Contents for IT-REFERENCE 20i

Page 1: ...MMETRICAL POWER CONDITIONER CONDITIONNEUR D ALIMENTATION SYM TRIQUE DISCRET ACONDICIONADOR DE POTENCIA SIMETRICA Y DISCRETA OWNER S MANUAL GUIDE DE L UTILISATEUR MANUAL DEL PROPIETARIO DISCRETE SYMMET...

Page 2: ......

Page 3: ...i Guide De L Utilisateur IT REFERENCE 20i DISCRETE SYMMETRICAL POWER CONDITIONER CONDITIONNEUR D ALIMENTATION SYM TRIQUE DISCRET ACONDICIONADOR DE POTENCIA SIMETRICA Y DISCRETA OWNER S MANUAL GUIDE DE...

Page 4: ...ymmetrical power This dramatically reduces AC noise ensuring peak operation of your critical components For the first time you will see and hear your theater or audio system as it should be uncompromi...

Page 5: ...ence 20i has been dropped or the enclosure damaged Power Source The power source to which the IT Reference 20i is connected should be adequate for use at 20 Amps Though the system may function with a...

Page 6: ...mponent AC cords to the IT Reference 20i s four Discrete power banks We recommend separating digital processors DVD s and CD players from pre amplifiers tuners and tape machines Further video monitors...

Page 7: ...symmetrical AC power output whereby both the neutral and positive leads of the AC cable run at 60 Volts AC in opposing polarity referenced to ground 0 Volts AC This is but one of the IT Reference 20i...

Page 8: ...an additional cable to connect from their output to the control device requiring protection All in line surge suppressors feature our exclusive ground contamination free technology This aids in elimin...

Page 9: ...urman determines that the damage did not result from the Occurrence or that no Occurrence in fact took place or Furman determines that the connected equipment was not used under normal operating condi...

Page 10: ...ing power amplifiers to work more efficiently Linear Noise Attenuation Transverse Differential Mode 20 dB from 1Khz 2 kHz 40 dB from 2Khz 100 kHz 80 dB from 100 kHz 1GHz Linear attenuation curve from...

Page 11: ...11 FRAN AIS ENGLISH...

Page 12: ...itiques de votre syst me il masque les signaux de faible intensit et d t riore le rendement Ces signaux sont importants car ils transmettent les harmoniques essentielles et l ambiance au niveau du son...

Page 13: ...opri t originaux en plus de nous permettre de vous informer des mises niveau ou de vous transmettre d autres renseignements importants Information sur la s curit et avertissements Veuillez lire et app...

Page 14: ...re si vous faites face au panneau arri re Ensuite la fiche Edison m le doit tre reli e un prise appropri e se reporter aux recommandations susmentionn es sur le courant nominal Ce cordon c a v hicule...

Page 15: ...ndes de courant de cr te sont beaucoup plus importantes l appel de puissance total maximum en continu peut tre limit selon une plage variant entre 1 500 et 2 100 W par unit IT Reference 20i utilis e L...

Page 16: ...nce 20i ou du syst me d alimentation d un composant connect Dans ce cas nous devons prioriser la s curit La solution est notre disjoncteur de fuite la terre GFCI Ground Fault Circuit Interrupter Le GF...

Page 17: ...est de moins de 0 1 dB 1 GHz Pour brancher vos c bles ces dispositifs de protection en ligne il vous suffit de suivre les indications in et out indiqu es c t des connecteurs Cable et ou Satellite REMA...

Page 18: ...utilis sous des conditions normales d utilisation ou selon les instructions propos es par le Fabricant de l quipement connect Tous les limiteurs de surtension de Furman doivent tre reli s directement...

Page 19: ...dance d entr e c a de mani re en maximiser le fonctionnement Att nuation du bruit Mode transversal diff rentiel 20 dB de 1 kHz 2 kHz 40 dB de 2 kHz 100 kHz 80 dB de 100 kHz 1 GHz courbe d att nuation...

Page 20: ...Notes...

Page 21: ......

Page 22: ...Notes...

Page 23: ......

Page 24: ...1690 Corporate Circle Petaluma California USA 94954 Phone 877 486 4738 Fax 707 763 1310 www FurmanSound com ITREF20iM_Rev2a...

Reviews: