connector.  Watt ratings are simply added to determine the total system RMS current draw.  It should also be noted that the 
IT-Reference 20i’s Power Factor Technology circuitry has no actual effect on the power drawn from your utilities’ power meter.  
The IT-Reference 20i draws a mere 8.5 Watts independent of other components, so it may be left on at all times.

Suggested AC Connection

Soft Start - Continuous Use and Break-In Time

When power is first applied to the IT-Reference 20i, (the front panel breaker-power toggle must be switched to the “on” 
position) the Soft Start feature is activated.  There is an audible “clack” when the IT-Reference is first turned on or off.  This 
sound is produced by the Soft Start circuit’s 30 Amp relay engaging or disengaging.  There is nothing in the IT-Reference 
20i’s construction, design, or componentry to wear over the life time of the product, and there is no power draw from your 
electric service meter aside from the LED power indicator, relay, and GFCI protection circuit. For this reason the IT-Reference 
20i may be left with its power engaged permanently at a cost of pennies per month. This is an added benefit, as many audio/
videophiles find performance improves significantly when leaving low-powered components permanently charged (turned 
on).  This is true of the IT-Reference 20i.  Though it will function flawlessly right from its shipping carton, the performance of its 
circuit parts will improve after approximately two weeks of continuous use or “break-in.”  

Ground Fault Interrupter (GFCI)

The IT-Reference 20i’s “Discrete Symmetrical Filtered AC outlets” incorporate symmetrical AC power output, whereby both the 
neutral and positive leads of the AC cable run at 60 Volts AC in opposing polarity, referenced to ground (0 Volts AC).  This is 
but one of the IT-Reference 20i’s advantages over other AC-filter/protection designs.  

Though virtually all domestically produced electronic equipment is designed to detect electrical shorts and other potentially 
dangerous equipment problems in the Line lead referenced to its Neutral, this is inadequate when power is symmetrical.  With 
the IT-Reference 20i, both neutral and positive legs contain 60 VAC relative to their Ground tab.  This is not a problem or safety 
hazard, unless there is a defect in either the IT-Reference 20i’s transformer, or the power supply of a connected component.  In 
this instance, we need to assure that safety is always maintained.  The solution is our GFCI (ground fault circuit interrupter).   

The Furman GFCI detects any imbalance in the current flowing in the two hot legs. The missing current is presumed to be 
flowing through the ground conductor (the round pin on an AC outlet).  Ground current often indicates a dangerous partial 
or full short circuit.  If an imbalance is detected, the GFCI will trip the main circuit breaker/power switch.  To restore operation, 
correct the fault and turn the unit on again. 5 mA of current is enough to cause the GFCI to trip; to troubleshoot this type 
of problem, start with nothing connected to the IT-Reference 20i.  Then, add each piece of equipment until the GFCI trips.  
Contact the manufacturer of the suspect unit for possible solutions.

Telco Protectors (x2)

AC Cord

Cable / Satellite

Protectors (x3)

Powered

Subwoofer

Plasma/LCD

Monitor/Projector

Turntable

2 - 7
Channel
Amplifier

VCR
or DVR

DVD/
HD-DVD/
Blu-Ray Player

Audio
Pre-Amplifier /
Processor

Satellite
Receiver / 
Cable Box

Mono
Block
Amplifier

Summary of Contents for IT-REFERENCE 20i

Page 1: ...MMETRICAL POWER CONDITIONER CONDITIONNEUR D ALIMENTATION SYM TRIQUE DISCRET ACONDICIONADOR DE POTENCIA SIMETRICA Y DISCRETA OWNER S MANUAL GUIDE DE L UTILISATEUR MANUAL DEL PROPIETARIO DISCRETE SYMMET...

Page 2: ......

Page 3: ...i Guide De L Utilisateur IT REFERENCE 20i DISCRETE SYMMETRICAL POWER CONDITIONER CONDITIONNEUR D ALIMENTATION SYM TRIQUE DISCRET ACONDICIONADOR DE POTENCIA SIMETRICA Y DISCRETA OWNER S MANUAL GUIDE DE...

Page 4: ...ymmetrical power This dramatically reduces AC noise ensuring peak operation of your critical components For the first time you will see and hear your theater or audio system as it should be uncompromi...

Page 5: ...ence 20i has been dropped or the enclosure damaged Power Source The power source to which the IT Reference 20i is connected should be adequate for use at 20 Amps Though the system may function with a...

Page 6: ...mponent AC cords to the IT Reference 20i s four Discrete power banks We recommend separating digital processors DVD s and CD players from pre amplifiers tuners and tape machines Further video monitors...

Page 7: ...symmetrical AC power output whereby both the neutral and positive leads of the AC cable run at 60 Volts AC in opposing polarity referenced to ground 0 Volts AC This is but one of the IT Reference 20i...

Page 8: ...an additional cable to connect from their output to the control device requiring protection All in line surge suppressors feature our exclusive ground contamination free technology This aids in elimin...

Page 9: ...urman determines that the damage did not result from the Occurrence or that no Occurrence in fact took place or Furman determines that the connected equipment was not used under normal operating condi...

Page 10: ...ing power amplifiers to work more efficiently Linear Noise Attenuation Transverse Differential Mode 20 dB from 1Khz 2 kHz 40 dB from 2Khz 100 kHz 80 dB from 100 kHz 1GHz Linear attenuation curve from...

Page 11: ...11 FRAN AIS ENGLISH...

Page 12: ...itiques de votre syst me il masque les signaux de faible intensit et d t riore le rendement Ces signaux sont importants car ils transmettent les harmoniques essentielles et l ambiance au niveau du son...

Page 13: ...opri t originaux en plus de nous permettre de vous informer des mises niveau ou de vous transmettre d autres renseignements importants Information sur la s curit et avertissements Veuillez lire et app...

Page 14: ...re si vous faites face au panneau arri re Ensuite la fiche Edison m le doit tre reli e un prise appropri e se reporter aux recommandations susmentionn es sur le courant nominal Ce cordon c a v hicule...

Page 15: ...ndes de courant de cr te sont beaucoup plus importantes l appel de puissance total maximum en continu peut tre limit selon une plage variant entre 1 500 et 2 100 W par unit IT Reference 20i utilis e L...

Page 16: ...nce 20i ou du syst me d alimentation d un composant connect Dans ce cas nous devons prioriser la s curit La solution est notre disjoncteur de fuite la terre GFCI Ground Fault Circuit Interrupter Le GF...

Page 17: ...est de moins de 0 1 dB 1 GHz Pour brancher vos c bles ces dispositifs de protection en ligne il vous suffit de suivre les indications in et out indiqu es c t des connecteurs Cable et ou Satellite REMA...

Page 18: ...utilis sous des conditions normales d utilisation ou selon les instructions propos es par le Fabricant de l quipement connect Tous les limiteurs de surtension de Furman doivent tre reli s directement...

Page 19: ...dance d entr e c a de mani re en maximiser le fonctionnement Att nuation du bruit Mode transversal diff rentiel 20 dB de 1 kHz 2 kHz 40 dB de 2 kHz 100 kHz 80 dB de 100 kHz 1 GHz courbe d att nuation...

Page 20: ...Notes...

Page 21: ......

Page 22: ...Notes...

Page 23: ......

Page 24: ...1690 Corporate Circle Petaluma California USA 94954 Phone 877 486 4738 Fax 707 763 1310 www FurmanSound com ITREF20iM_Rev2a...

Reviews: