background image

4

P-1400 AR E OWNER’S MANUAL

FURMAN P-1400 AR E FEATURES

True RMS Voltage Regulation 

• 

- A 6 amp ultra-low noise toroidal autoformer with microprocessor control

SMP 

• 

(Series Multi-Stage Protection) with EVS (Extreme Voltage Shutdown)

LiFT

• 

 (Linear Filtering Technology) with zero ground contamination

Ten total regulated, filtered and protected rear panel AC outlets and one front panel convenience outlet

• 

Very low stray magnetic field leakage

• 

230V or 240V output (switchable)

• 

Dimmable/Switchable true RMS digital ammeter and laboratory precise voltmeter

• 

Tri-color voltage range indicator (complements numerical voltage reading - even when viewed at a distance from the display)

• 

Front panel USB connector charges most portable media devices and cell phones

• 

BNC connector on the rear panel allows you to attach any standard (12VAC 0.5 amp) gooseneck lamp to illuminate the rear of 

• 

your rack (Furman GN-I and GN-LED accessory gooseneck lamps (sold separately) are recommended for this application) 
6 amp (1400 watt) maximum current capacity

• 

Detachable 2.5 meter AC cord with Schuko plug (standard) 

• 

Five year limited warranty

• 

INTRODUCTION

 

Thank you for purchasing a Furman Prestige Series Voltage Regulator/Power Conditioner, and congratulations on your choice.  The 
Prestige Series P-1400 AR E features Furman’s True RMS Auto Regulation, Series Multi-Stage Protection (SMP) circuit, and our exclusive 
Linear Filtering Technology (LiFT).  Together, these technologies comprise precisely what our customers have grown to expect from 
Furman: uncompromised protection and purification.  The P-1400 AR E has been precisely engineered to more than meet the critical 
demands of recording studios, broadcast facilities, and discerning musicians alike.   

The Furman P-1400 AR E is intended to protect sensitive electronic equipment from problems caused by AC line voltage irregularities—
brownouts or over-voltages that can cause audio tonal changes, digital equipment malfunction (such as loss of MIDI programs or other 
data), or, in extreme cases, permanent damage. It accepts input voltages between 188V-270V and converts them to a steady, stable 
output of either 230V or 240V (switchable), plus or minus 10 volts. Voltages approximately ±10% beyond that range may be converted 
to usable levels, depending on the requirements of the equipment. This stable voltage protects equipment and allows optimal 
performance. If you frequently move your rack to different locations, derive power from generators, use excessively long extension 
cords, travel internationally, or are in an area prone to brownouts, you will benefit from the use of a Furman P-1400 AR E.  

DESCRIPTION

True RMS Voltage Regulation Technology

True RMS Voltage Regulation is designed around an ultra-low noise eight-tap toroidal autoformer.  A microprocessor within the P-1400 
AR E monitors the incoming RMS voltage with each cycle, measuring the phase angle in time with the advancing cycle.  Most com-
mercial voltage regulators using multiple-tapped transformers switch taps at uncontrolled times. This creates voltage spikes and clicks 
that can leak into audio. When a voltage fluctuation requires correction by the P-1400 AR E, True RMS Voltage Regulation advances a 
new tap with less stress and in turn avoids distortion to the AC waveform. Hysteresis in the P-1400 AR E circuits avoids the unneces-
sary switching back and forth between the adjacent taps (or “chatter”) found in many commercial voltage regulators. If necessary, 
True RMS Voltage Regulation technology can switch taps as often as once each cycle and do so with a shorter recovery time than a 
commercial voltage regulator. In addition and unlike voltage regulators that employ ferroresonant transformers, the P-1400 AR E is not 
sensitive to small errors in line frequency, making it ideal for use with generators.
The P-1400 AR E has ten outlets on the rear panel and one convenience outlet on the front panel. All are functionally interchangeable. 
The outlets are regulated, surge-suppressed, and linearly filtered, making the unit a full-function power conditioner. The autoformer’s 
toroidal design assures minimal leakage of stray magnetic fields.  

Note:

 

P-1400 AR E is for use with AC voltage only. DC voltages should never be applied. Also, it does not change or regulate line  

Frequency. The output frequency will always be the same as the incoming frequency. 

SMP (Series Multi-Stage Protection) with EVS (Extreme Voltage Shutdown)

Furman’s SMP (Series Multi-Stage Protection) surge suppression virtually eliminates service calls and costly “down time”.  Traditional 
surge suppression circuits sacrifice themselves when exposed to multiple transient voltage spikes, requiring the dismantling of your 
system and repair of your surge suppressor.  Not so with Furman’s SMP.  With SMP, damaging transient voltages are safely absorbed, 
clamped, and dissipated.  Your connected equipment is protected, while your P-1400 AR E protects itself!   

Summary of Contents for P-1400 AR E Prestige Series

Page 1: ......

Page 2: ......

Page 3: ...S RESERVED PRINTED IN CHINA ENGLISH Page 4 FRAN AIS Page 12 ESPA OL Page 20 P 1400 AR E OWNER S MANUAL P 1400 AR E GUIDE DE L UTILISATEUR P 1400 AR E MANUAL DEL PROPIETARIO DEUTSCH Page 28 Page 36 P 1...

Page 4: ...optimal performance If you frequently move your rack to different locations derive power from generators use excessively long extension cords travel internationally or are in an area prone to brownou...

Page 5: ...e user whether voltage is in or out of a safe range The ammeter accurately measures current draw for an instant analysis of system requirements The P 1400 AR E is equipped with eleven regulated outlet...

Page 6: ...hrough the 3 stages of brightness Voltage Range Indicator This tri color Voltage Range indicator is located in the lower left corner of the digital voltage meter lens assembly When the incoming AC vol...

Page 7: ...r located to the lower right of the voltage meter will not illuminate If this happens some level of protection from voltage surges will remain but the Furman s clamping voltage rating will be compromi...

Page 8: ...pt showing the purchase date Shipping charges to Furman headquarters must be prepaid by the purchaser of the product Furman shall at its own expense furnish a replacement product or at Furman s option...

Page 9: ...ground leakage SPIKE CLAMPING VOLTAGE 376 VAC peak 3 000 amps RESPONSE TIME 1 nanosecond MAXIMUM SURGE CURRENT 6 500 AMPS NOISE ATTENUATION 10 dB 10kHz 40 dB 100kHz 50 dB 500kHz DIMENSIONS 19 W x 12...

Page 10: ...10 P 1400 AR E OWNER S MANUAL AR VOLTAGE RANGE AR OUTPUT CURRENT RANGE...

Page 11: ...11 FRAN AIS ENGLISH Espa ol DEUTSCH NOTES...

Page 12: ...eils num riques tel que la perte de logiciels MIDI ou d autres donn es ou dans des cas ex tr mes des dommages permanents Ce mod le accepte des tensions d entr e de r seau alternatif et les convertit e...

Page 13: ...es pouvaient en effet nuire aux performances du son et de l image plus qu elles ne les aidaient cause du pic r sonnant de leur conception v tuste non lin aire Dans certaines conditions ces technologie...

Page 14: ...yez pas de r parer votre mod le P 1400 AR E au del des instructions fournies par ce manuel Toute autre r paration devrait tre confi e un technicien qualifi INSTALLATION Gr ce la conception toro dale d...

Page 15: ...ible lors d une utilisation normale L indicateur de tension d extr mit surveille un risque commun dans l industrie du spectacle aussi bien que l mission distance c blant des d fauts tels que le raccor...

Page 16: ...mettre le traitement de toute r clamation concernant la garantie Furman une marque de Panamax Inc garantit son P 1400 AR E le Produit comme suit Furman garantit l acheteur original que le produit vend...

Page 17: ...NSION DE BLOCAGE DES SURTENSIONS pic de 376 VCA 3000 A TEMPS DE R ACTION 1 nanoseconde COURANT MAXIMUM DE SURTENSION 6500 A ATT NUATION DU BRUIT 10 dB 10kHz 40 dB 100 kHz 50 dB 500 kHz DIMENSIONS 19 p...

Page 18: ...ILISATEUR GAMME DE TENSION DE L AR COURANT DE SORTIE DE L AR TENSION D ENTR E TENSION DE RENDEMENT Arr t haute tension Gamme fonctionnelle Gamme r glementaire Arr t de basse tension COURANT DE SORTIE...

Page 19: ...19 FRAN AIS ENGLISH Espa ol DEUTSCH NOTES...

Page 20: ...ipo digital como p rdida de programas MIDI u otra informaci n o en casos extremos da o permanente Acepta una amplia gama de voltajes de CA de entrada y los convierte en una salida regular y estable de...

Page 21: ...0 dB de ruido a la l nea de CA entrante Y lo que es peor aun la p rdida de informaci n digital la necesidad de reiniciar las preconfiguraciones digitales o la destrucci n de transforma dores digitales...

Page 22: ...geridas de los estantes son en la parte superior o en la parte inferior Como con cualquier equipo montado en estantes aseg rese de utilizar tornillos mec nicos 10 32 para montar en los agujeros de col...

Page 23: ...rriente antes de que pueda producirse alg n da o Cuando le aplique corriente por primera vez al P 1400 AR E el indicador de Voltaje extremo se iluminar con una luz roja brillante si el voltaje de entr...

Page 24: ...00 AR E el Producto de la siguiente manera Furman garantiza al comprador original del producto que el producto vendido de acuerdo con este documento no poseer ning n defecto de material ni de mano de...

Page 25: ...erra PINZAMIENTO DE VOLTAJE DE SUJECI N PARA PICOS 376 VCA m ximo a 3000 amperes TIEMPO DE RESPUESTA 1 nanosegundo SOBRECORRIENTE M XIMA 6500 AMPERES ATENUACI N DEL RUIDO 10 dB a 10kHz 40 dB a 100kHz...

Page 26: ...RIO GAMA DEL VOLTAJE DE AR CORRIENTE DE SALIDA DE AR CORRIENTE DE SALIDA DISPONIBLE Parada de la baja tensi n Parada de alto voltaje Gama funcional Gama de regla CORRIENTE DE SALIDA DISPONIBLE VOLTAJE...

Page 27: ...27 FRAN AIS ENGLISH Espa ol DEUTSCH NOTAS...