       (3)  if all of the leds on the voltmeter  
 

flash, the input voltage is marginally  

 

high. Power to the Power factor  

 

Pro’s outlets will remain on unless the  

 

incoming voltage rises above the  

 

extreme Voltage shutdown (eVs) 

             cut-off voltage (135 - 140 volts).

the Power factor Pro’s voltmeter has a basic 

accuracy of plus or minus two volts, and 
extreme cold or heat may cause an additional 
one volt of error (four volts and two volts for 
Power factor Pro e).

NOTE

: although the Power factor correction 

will more than compensate for peak current 
demands, the Power factor Pro does not 
compensate for 

sustained

 high or low line 

voltage. if you derive power from generators, 

travel internationally, or are in an area prone 
to extreme brownouts, you may benefit from 
the use of one of furman’s aC line Voltage 
regulators.  

on/off rocker Switch:

 

this 15 amp capacity power switch is 

specifically designed to stand up to the 
enormous high inrush current demands placed 
by many instrument amplifiers. Additionally, the 
semi-transparent rocker lights when switched 

to the “on” position.

extreme Voltage Shutdown (eVS) Indicator:

 

this led is normally off. it monitors a hazard 

unfortunately common in the entertainment 
industry: wiring faults – for example, accidental 
connection to 220VaC where 120VaC is 
expected, or an open neutral from a 208 or 

240VaC feed. the Power factor Pro’s sMP+ 

circuit senses voltages that are so high that 
operation would be impossible and shuts the 
power down before damage can occur.  upon 
initially applying power to these units, the 
extreme Voltage indicator led will be lit if the 
input voltage is above the extreme voltage 
cutoff, and power will not be applied to the 
unit’s outlets. if the unit has been operating 
with an acceptable input voltage and then that 

voltage goes above 135V, it will shut off power 

to the outlet and the extreme Voltage led will 
light.

note:

 if the mains power is above the high 

cutoff voltage and has caused the unit to 
remove power from its outlets, it cannot restore 
power without the operator manually turning 
the unit off, then on again. avoid turning the 
unit back on without checking the source of the 
problem first, and perhaps changing the AC 
source.

4

Mains Vltg.  Voltage Status 

  Voltmeter Reading 

Outlets

80-90 

Low Marginal 

The 90V LED mark flashes 

ON

90-104 

low 

Meter reads in low red 

on

106-108 

Medium low 

Meter reads in low Yellow 

on

110-120 

normal 

Meter reads in Green 

on

122-124 

Medium High 

Meter reads in High Yellow 

on

126-128 

High 

Meter reads in High red 

on

130-140 

High Marginal 

all Meter leds flash 

on

above 140 

extreme (shutdown) 

Meter off—extreme Voltage led illuminates off

   

Summary of Contents for PF-Pro R

Page 1: ...power factor pro manual ...

Page 2: ...lay in a stadium bar or rehearsal space they all have one thing in common the AC power is supplied from your local utility What s worse is that the power factor supplied from your building s AC outlet is typically poor thanks to increasingly over taxed power lines and raised line impedance In fact the quality of AC power has been so poor for so long most musicians have no idea how great their ampl...

Page 3: ...rman Power Factor Pro Power Conditioner please be sure to read this manual carefully before using WAR N I N G To reduce the risk of electrical shock do not expose this equipment to rain or moisture Dangerous high voltages are present inside the enclosure Do not remove the covers Refer servicing to qualified personnel only The lightning flash with an arrowhead symbol is intended to alert the user t...

Page 4: ... Pro also features a detachable 10 foot 14 gauge heavy duty power cable The Power Factor Pro offers a 20 segment LED bar graph meter that displays incoming voltage between 90 and 128 volts in 2 volt increments The normal range voltages are indicated in green with moderately and extremely high or low voltages in yellow and red respectively The voltmeter s accuracy is 2 volts It can easily be recali...

Page 5: ...ing faults for example accidental connection to 220VAC where 120VAC is expected or an open neutral from a 208 or 240VAC feed The Power Factor Pro s SMP circuit senses voltages that are so high that operation would be impossible and shuts the power down before damage can occur Upon initially applying power to these units the Extreme Voltage indicator LED will be lit if the input voltage is above th...

Page 6: ...rrants its PF Pro and PF Pro R the Product as follows Manufacturer warrants to the original Purchaser of the Product that the Product sold hereunder will be free from defects in material and workmanship for a period of three years from the date of purchase The Purchaser of the product is allowed fifteen days from the date of purchase to complete warranty registration by mail or on line at the Furm...

Page 7: ...This warranty shall be cancelable by Manufacturer at its sole discretion if the product is modified in any way without written authorization from Furman Sound This warranty also does not apply to Products upon which repairs have been affected or attempted by persons other than pursuant to written authorization by Manufacturer THIS WARRANTY IS EXCLUSIVE The sole and exclusive obligation of Manufact...

Page 8: ...may be used SPECIFICATIONS Current rating 12 amps E versions 7 amps Operating Voltage 90 to 140 VAC E versions 180 to 280 VAC Over Voltage Shutdown 140 VAC typically E versions 280 VAC typically Voltmeter Accuracy 2 VAC calibrated with internal trimpot adjustments Spike Protection Modes Line to neutral zero ground leakage Spike Clamping Voltage 188 Vpk 3 000 amps 133 VAC RMS tested to UL 1449 6 00...

Reviews: