background image

4

PL-PLUS C E OWNER’S MANUAL

FURMAN’s PL-PLUS C E FEATURES

SMP

• 

 (Series Multi-Stage Protection) with 

EVS

 (Extreme Voltage Shutdown)

LiFT

• 

 (Linear Filtering Technology) with zero ground contamination

20-segment LED tri-color AC voltage meter (allows easy verification of voltage range from a distance or in poor lighting) 

• 

Two 

• 

Smooth Track

 retractable, long-life, low-heat, front panel LED lights with dimmer-power switch for  rack illumination 

BNC connector on the rear panel accepts  any standard (12VAC 0.5 amp) gooseneck lamp to illuminate the rear of your rack   

• 

(Furman GN-I and GN-LED accessory gooseneck lamps are best for this application)

Ten rear panel AC outlets and one front panel convenience outlet

• 

10A (2300 watt) capacity with 10A circuit breaker

• 

Five year limited warranty

• 

INTRODUCTION

 

Thank you for purchasing a Furman Classic Series power conditioner, and congratulations on your choice. Classic Series power 
conditioners feature Furman’s revolutionary Series Multi-Stage Protection (

SMP

) circuit, Extreme Voltage Shutdown (

EVS

), and our 

exclusive Linear Filtering Technology (

LiFT

).  Together, these technologies comprise precisely what our customers have come to expect 

from Furman - uncompromised AC protection and purification.  Our Classic Series has been precisely engineered to exceed the critical 
demands of audio/video professionals, contractors, broadcasters, and musicians alike.  

SMP (SERIES MULTI-STAGE PROTECTION)

Furman’s SMP surge suppression virtually eliminates service calls and costly “down time”.  Traditional surge suppression circuits sacri-
fice themselves when exposed to multiple transient voltage spikes, requiring the dismantling of your system and repair of your surge 
suppressor.  Not so with Furman’s SMP.  Damaging transient voltages are safely absorbed, clamped, and dissipated.  Your connected 
equipment is protected, while your Furman protects itself!  

 

Unique to Furman’s SMP is its unparalleled clamping voltage, defined as the amount of voltage that is allowed to pass through to your 
equipment when the protection device is subjected to a transient surge or spike.  While other designs offer clamping voltages that are 
well above 600 Vpk, Furman’s SMP clamps at 376 Vpk, (266 VAC RMS) even when tested with multiple 6000 Vpk - 3000 amp surges!  
This unprecedented level of protection is only available with Furman’s SMP technology.  

EVS (EXTREME VOLTAGE SHUTDOWN)

Furman’s trusted over-voltage (EVS) circuitry protects against prolonged overvoltage conditions, such as accidental connections to 
330+ VAC, or an intermittent neutral.  It does so by monitoring the incoming voltage and, when an unsafe condition is detected, 
triggering a relay which shuts off the incoming power until the overvoltage condition is corrected and the power switch is reset.

LIFT (LINEAR FILTERING TECHNOLOGY)

Unfortunately, traditional AC power conditioners have been designed for unrealistic laboratory conditions.  Prior technologies, wheth-
er multiple-pole or conventional series-mode filters, could actually harm audio and video performance more than they help, due to 
the resonant peaking of their antiquated, non-linear designs.  Under certain conditions, these designs can actually add more than 10 
dB of noise to the incoming AC line!  Worse still, lost digital data, the need to reboot digital presets, or destruction of sensitive digital 
converters are frequently caused by excessive voltage spikes and AC noise contaminating the equipment ground.  Furman’s LiFT takes 
a different approach, ensuring optimal performance through linear AC noise filtering with no ground contamination.

PL-PLUS C E ADDITIONAL FEATURES

The PL-PLUS C E features 

Smooth Track

 LED rack lights which produce virtually no heat and provide an extremely long lifespan. A dim-

mer control for the rack lights allows the user to adjust the level of illumination (by rotating clockwise/counterclockwise) or switch the 
lamps on and off (by pushing the knob in).  A rear mounted BNC jack accepts any standard (12VAC 0.5 amp) gooseneck lamp for rear 
rack illumination. 

Additionally, the PL-PLUS C E offers a tri-color multi-segment LED AC voltage meter that displays incoming voltage in 2-volt steps.  The 
voltmeter’s accuracy is ±2.0 volts.  This informs the user whether the voltage is in or out of a safe range, even from a distance too grea 
to accurately read the displayed voltage. 

Summary of Contents for PL-PLUS C E

Page 1: ......

Page 2: ......

Page 3: ...S RESERVED PRINTED IN CHINA ENGLISH Page 4 FRAN AIS Page 10 ESPA OL Page 16 PL PLUS C E OWNER S MANUAL PL PLUS C E GUIDE DE L UTILISATEUR PL PLUS C E MANUAL DEL PROPIETARIO DEUTSCH Page 22 Page 28 PL...

Page 4: ...ient surge or spike While other designs offer clamping voltages that are well above 600 Vpk Furman s SMP clamps at 376 Vpk 266 VAC RMS even when tested with multiple 6000 Vpk 3000 amp surges This unpr...

Page 5: ...into the unit 7 Your Furman conditioner should be serviced by qualified service personnel when The power supply cord or the plug has been frayed kinked or cut Objects have fallen or liquid has been sp...

Page 6: ...sion device to absorb without some degree of damage such as a direct lightning hit in an outdoor application In the rare instance that this occurs the green Protection OK LED indicator located to the...

Page 7: ...YEAR LIMITED WARRANTY SAVE YOUR SALES RECEIPT The receipt is your proof of purchase and confirms the product was purchased at an authorized Furman dealer It will need to be submitted to Furman in orde...

Page 8: ...y is determined to be void or il legal the remainder shall remain in full force and effect SPECIFICATIONS CURRENT RATING 10 amps OPERATING VOLTAGE 180 to 274 VAC OVER VOLTAGE SHUTDOWN 275 VAC typicall...

Page 9: ...PLUS C E REAR PANEL convenience outlet dual pull out lamps 10 amp circuit breaker bnc lamp connector bnc lamp power switch isolated ac outlet banks ac inlet with iec female to 10a schuko plug front la...

Page 10: ...votre syst me Ce n est pas le cas avec le circuit SMP de Furman Les voltages transitoires nuisibles sont absorb s contraints et dissip s de fa on s curitaire Votre quipement branch est prot g tandis...

Page 11: ...tallation 1 Veuillez lire et respecter toutes les consignes de s curit et le mode d emploi avant d installer votre module filtre de la s rie Classic de Furman Conservez ces documents pour consultation...

Page 12: ...divertissement de l mission en ext rieur et de l audio vid o soit les d fauts de c blage Par exemple s il y avait une connexion accidentelle dans du 330 VCA tandis que 220 240 VCA tait requis ou une s...

Page 13: ...situ sur le panneau arri re adjacent au cordon d alimentation a t d clench cause d une surtension Solution D branchez une portion d quipement qui est branch au module filtre Furman et appuyez sur le...

Page 14: ...AIS PAS LIMIT AUX GARANTIES IMPLICITES L GARD DE LA QUALIT LOYALE ET MARCHANDE VISANT UN BUT PARTICULIER Furman ne garantit pas contre les dommages ou d fauts issus d une utilisation inappropri e ou d...

Page 15: ...enance prise de courant deux lampes r tractables disjoncteur de 10A prise de bnc lampe bnc lampe commutateur lectrique banques d isolement de sortie C A admission C A avec la femelle du CEI la prise d...

Page 16: ...smantelamiento de su sistema y la reparaci n del supresor de sobretensi n Esto no sucede con el SMP de Fur man Los voltajes transitorios perjudiciales se absorben se contienen y se disipan con segurid...

Page 17: ...2 No debe utilizar el acondicionador de energ a Serie Classic cerca del agua por ejemplo cerca de tinas lavamanos fregaderos de cocina recipientes para lavar ropa en s tanos con humedad ni cerca de u...

Page 18: ...iento interrumpe el suministro de energ a antes de que se produzcan da os Al conectar la energ a al PL PLUS C E el indicador de voltaje extremo se pondr de color rojo brillante si el voltaje de entrad...

Page 19: ...rotection OK Protecci n activada no est encendido Causa posible La salida de CA donde est conectado el acondicionador Furman no tiene voltaje de CA o el sistema de circuitos de protecci n de su unidad...

Page 20: ...producto ni los defectos ni da os que surjan de la instalaci n incorrecta Furman puede cancelar esta garant a a su entera discreci n si el producto se modifica en cualquier forma sin una autorizaci n...

Page 21: ...tomacorriente para servicio dos l mparas retr ctiles disyuntor de 10A conector bnc para la lampara interruptor del conector bnc bancos aislados de los enchufes de ca entrada de CA con IEC hembra to 10...

Page 22: ...cher absorbiert abgeschnitten und abgeleitet Ihre angeschlossene Ausr stung ist gesch tzt w hrend Ihr Furman sich selbst sch tzt Einzigartig f r Furman s SMP ist die beispiellose Clamping Spannung d h...

Page 23: ...schekorb in einem nassen Fundament oder in der N he eines Schwimmbeckens verwendet werden 3 Stellen Sie Ihren Conditioner der Classic Serie nicht in die N he von Heizl ftern Hitzeregistern fen und and...

Page 24: ...Spannung zu den Ausg ngen abgeschaltet und die Extremspannungs LED leuchtet auf HINWEIS Falls die Netzspannung den hohen Spannungsgrenzwert berschreitet und bewirkt hat dass der EVS Kreis die Ausg nge...

Page 25: ...Furman auf 3 Symptom Extremspannungsanzeige EVS leuchtet M gliche Ursache Die Eingangsspannung berschreitet 275V wodurch die Spannung zu den Ger teausg ngen abge schaltet wird Dar ber hinaus verhinde...

Page 26: ...en aufhebbar wenn das Produkt ohne die schriftliche Genehmigung seitens Furmans oder Panamax Inc in irgendeiner Art ver ndert wurde Diese Garantie deckt auch nicht Produkte ab an denen Reparaturen von...

Page 27: ...sanschluss herausziehbare Verdoppelunglampen 10 ampere stromunterbrecher bnc Lampenverbindungsst ck bnc Lampen Netzschalter lokalisierte Wechselstrom Anschlussbanken Wechselstrom Eingang mit Iec Frau...

Page 28: ...Smooth Track BNC 12 0 5 GN I GN LED Furman 10 A 2300 10A 5 Furman Classic Classic Furman SMP EVS LiFT Furman Classic SMP SMP Furman SMP Furman Furman SMP Furman 600 V SMP Furman 376 V 266 6000 V 3000...

Page 29: ...RAN AIS ENGLISH Espa ol DEUTSCH PL PLUS C E PL PLUS C E Smooth Track BNC 12 0 5 PL PLUS C E 2 2 0 Classic Furman 1 Classic Furman 2 Classic 3 4 PL PLUS C E Furman 220 240 60 10 5 6 7 Furman Protection...

Page 30: ...Classic Furman Smooth Track Classic BNC GN LED GN I Furman BNC BNC BNC Classic 10 EVS EVS EVS 330 220 240 330 EVS Furman PL PLUS C E Extreme Voltage 275 EVS PL PLUS C E PROTECTION OK SMP Furman Prote...

Page 31: ...AN AIS ENGLISH Espa ol DEUTSCH 20 80 256 4 1 180 2 PL PLUS C E EVS 275 3 Extreme Voltages 275 PL PLUS C E Furman 1 2 Protection OK Furman 220 240 Furman 3 Extreme Voltage EVS 275 175 Furman 215 245 Fu...

Page 32: ...sound com Furman 5 Furman Furman Furman Panamax Inc PL PLUS C E Furman Furman 707 763 1010 techsupport furmansound com Furman Furman Furman Furman Furman Furman Furman Panamax Inc Furman Panamax Inc F...

Page 33: ...33 FRAN AIS ENGLISH Espa ol DEUTSCH 1 6500 10 10 40 100 50 500 0 05 100 4 5 48 27 11 5 0 3 12 CE PL PLUS C E PL PLUS C E 10 BNC BNC AC AC iec schuko 10a...

Page 34: ...Notes...

Page 35: ...Notes...

Page 36: ...1690 Corporate Circle Petaluma California USA 94954 Phone 877 486 4738 Fax 707 763 1310 www FurmanSound com PL PLUSCE_RevA...

Reviews: