S A F E T Y
I N F O R M A T I O N

To obtain best results from your Furman Metered Six
Power Conditioner, please be sure to read this manual
carefully before using.

W A R N I N G

To reduce the risk of electrical shock, do not expose
this equipment to rain or moisture. Dangerous high
voltages are present inside the enclosure. Do not
remove the covers. Other than the light bulbs, there
are no user serviceable parts inside. Refer servicing to
qualified personnel only.

The lightning flash with an arrowhead symbol, (within
an equilateral triangle) is intended to alert the user to
the presence of un-insulated dangerous voltage within
the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock.

I M P O R T A N T
S A F E T Y
I N S T R U C T I O N S

(Please read prior to installation)

1.

Please read and observe all safety and operating
instructions before installing your Metered Six unit.
Retain these instructions for future reference.

2.

Your Metered Six unit should not be used near
water – for example, near a bathtub, washbowl,
kitchen sink, laundry tub, in a wet basement, near
a swimming pool, etc.

3.

Do not place your Metered Six unit near heat
sources such as radiators, heat registers, stoves,
or other appliances that produce heat.

4.

The PL-PROD, PL-PRODM, and PM-PRO should
only be connected to a 120 VAC, 60Hz, 20 amp
grounded electrical outlet. Outlets wired for 20
amps, may be identified by the T-shaped socket
opening that accept the perpendicular blades of
the PRO unit’s power plug. If you don’t have a 20-
amp outlet, have one installed by a qualified
electrician. Do not defeat the ground or change
polarization of the power plug.

5.

Route the power cord and other cables so that
they are not likely to be walked on, tripped over, or
stressed. Pay particular attention to the condition
of the cords and cables at the plugs, and the point
where they exit your Metered Six unit. To prevent
risk of fire or injury, damaged cords and cables
should be replaced immediately.

6.

Clean your Metered Six unit with a damp cloth
only. Do not use solvents or abrasive cleaners.
Never pour liquid on or into the unit.

7.

Your Metered Six unit should be serviced by
qualified service personnel when:

• The power supply cord or the plug has been frayed,

kinked, or cut.

• Objects have fallen or liquid has spilled into the unit.

• The unit has been exposed to rain or other moisture.

• The unit does not appear to operate normally or

exhibits a marked change in performance.

• The unit has been dropped, or the enclosure

damaged.

8.

Your Metered Six unit requires that a safety ground
be present for proper operation. Any attempt to
operate the unit without a safety ground is
considered improper operation and could
invalidate the warranty.

9.

Light bulbs are the only user-serviceable parts in
the PL-PLUSD, PL-PLUSDM, PL-PROD, and PL-
PRODM. Instructions for replacing them are on
page/s 4, 5, 6, and 7. The light tubes and end caps
become quite warm to the touch in normal
operation. To avoid burning your fingers, allow the
cap to cool completely before unscrewing it. If you
find that the heat from the tubes is excessive,
reduce the dimmer knob setting.

10. Do not attempt to service your Metered Six unit beyond

what is described in this manual. All other servicing
should be referred to qualified service personnel.

3

Summary of Contents for PL-PLUS

Page 1: ...Metered Six Series Owner s Manual ...

Page 2: ...laboratory quality Digital Voltage and True RMS Current meters Your Metered Six unit provides comprehensive protection from power line related transient voltages and noise while the 20 amp capable PRO units provide additional protection from wiring faults common to remote power theaters convention centers and AC generators The Metered Six s fast acting suppression circuit responds in less than a n...

Page 3: ...have one installed by a qualified electrician Do not defeat the ground or change polarization of the power plug 5 Route the power cord and other cables so that they are not likely to be walked on tripped over or stressed Pay particular attention to the condition of the cords and cables at the plugs and the point where they exit your Metered Six unit To prevent risk of fire or injury damaged cords ...

Page 4: ...ese units lamps come supplied with five watt night light bulbs Replacements are available at most hardware stores and may be purchased from Furman Sound service as well B U L B R E P L A C E M E N T Bulbs are easily replaced without removing the unit from the rack Here s How First pull the light tube s all the way out Unscrew the cap on the end of each tube to get access to the bulb Be careful not...

Page 5: ...age If you frequently move your rack to different locations derive power from generators use long extension cords travel internationally or are in an area prone to brownouts you may benefit from the use of one of Furman s AC Line Voltage Regulators On Off Rocker Switch This 15 amp capacity power switch is specifically designed to stand up to the enormous high inrush current demands placed by many ...

Page 6: ...tatus LED s to indicate abnormal power conditions Under extreme conditions these units will even keep themselves from turning on if the voltage is below 90VAC or above 140VAC During operation the unit will automatically shut down if the voltage rises above 140 volts O P E R A T I O N Retractable Rack Lights and Dimmer Control The PL PROD and PL PRODM utilize a dimmer control for the two retractabl...

Page 7: ...ndustry wiring faults for example accidental connection to 220VAC where 120VAC is expected The PL PROD PL PRODM and PM PRODM sense voltages that are so high or low that operation would be impossible and shuts the power down before damage can occur The cutoff voltages are under 90V or over 140V Upon initially applying power to these units the Extreme Voltage indicator LED will be lit if the input v...

Page 8: ...es with laboratory accuracy 1VAC The meter reads from 45 to 141 volts in 1 volt steps Additionally when their meter switch is set in the current mode it will measure the full AC load circulating through either the PL PRODM or PM PRODM 0 1Amp Because of the True RMS circuitry employed variable AC line distortions will not affect the accuracy of either measurement NOTE The PL PROD PL PRODM and PM PR...

Page 9: ...afety Information The PL PLUSD PL PLUSDM and PM 8DM are N R T L C listed 9 S P E C I F I C A T I O N S Current rating 20 amps 2400 watts at 120 VAC Input Voltage Range 0 to 250 VAC without damage Meter Accuracy Voltmeter 1VAC Ammeter 0 1 amps Spike Protection Modes Line to Neutral Neutral to Ground Line to Ground Clamping Voltage all modes Initial turn on at 200 volts TVSS rating 400V peak at 500 ...

Page 10: ...Conditioner Regulator or Surge Suppression product as the sole means of protection against a direct lightning hit The first line of defense against lightning should be a lightning arrestor installed on your building s electrical service entrance If your building does not have one contact your local power company or a contractor to have one installed S E R V I C E Before returning any equipment for...

Page 11: ... to repairs done by any company or individual other than the Furman factory or one of its Authorized Repair Stations All equipment being returned for repair must have a Return Authorization R A Number To get an R A number please call the Furman Service Department at 707 763 1010 ext 121 between the hours of 8 00 am and 5 00 pm US Pacific Time When returning equipment for repair please use the orig...

Page 12: ...d Inc 1997 South McDowell Blvd Petaluma California 94954 6919 USA Phone 707 763 1010 Fax 707 763 1310 Web www furmansound com E mail info furmansound com Designed and engineered in the U S A Manufactured in China ...

Reviews: