background image

6

PL-PRO C OWNER’S MANUAL

lamps are not in use, we recommend turning the dimmer fully counterclockwise, or pushing the knob to the off setting to maximize 
the life of the LED’s.  Whether the light tubes are fully extended or flush with the front panel, there will be no appreciable heat regard-
less of the dimmer setting due to the efficiency of our full light spectrum LED’s.  

All Furman Classic Series Conditioners feature a rear rack BNC socket which will accept any 12 VAC (0.5A) gooseneck lamp assembly 
(such as the Furman GN-LED or GN-I).  Simply slide the BNC plug over the socket and rotate clockwise until the connector snaps into 
the locked position.  The rear rack lamp can be powered on or off with the rear light switch which is adjacent to the BNC connector.  

ULTRA-LOW RESISTANCE MAGNETIC POWER SWITCH / CIRCUIT BREAKER:

Furman’s Classic Series 20 amp capacity power switch is specifically designed to stand up to the enormous high in-rush current de-
mands of many power amplifiers.  Additionally, Furman magnetic circuit breakers are not sensitive to temperature, and will not raise 
the AC impedance as do many, less costly thermal breaker.  If the 20 amp RMS current capacity of the PL-PRO C is exceeded, the spring 
tensioned-switch will immediately switch to the off position.  You will need to switch the toggle back to the on position once the prob-
lem is corrected (typically by eliminating one component, or until the RMS current does not exceed 20 amps or 2400 watts). 

 

EXTREME VOLTAGE SHUTDOWN (EVS) INDICATOR:

The Extreme Voltage LED Indicator is normally off.  It is located to the left of the power switch, though during normal use it will NOT be 
lit.  

The Extreme Voltage indicator monitors a hazard common in the entertainment, remote broadcast, and AV contractor industries: wir-
ing faults.  For example: accidental connection to 208VAC where 120VAC is expected, or an open series neutral from a 208 to 240VAC 
electrical service. The Furman EVS circuit senses voltages that are so high that operation would be impossible and shuts the power 
down before damage can occur.  

Upon initially applying power to the PL-PRO C, the Extreme Voltage indicator will illuminate to a bright red if the input voltage is above 
the extreme voltage cutoff.  When this occurs, power will not be applied to the PL-PRO C’s outlets. If the unit has been operating with 
an acceptable input voltage and subsequently that voltage exceeds 140V, it will shut off power to the outlets and the Extreme Voltage 
LED will light.

NOTE:

 If the mains power is above the high cutoff voltage and has caused the EVS circuit to remove power from the PL-PRO C’s out-

lets, it cannot restore power without the operator manually turning the unit off, then on again.  Avoid turning the unit back on without 
first checking the source of the problem and changing the AC source (if necessary).

PROTECTION OK INDICATOR:

Although the Furman SMP circuit assures virtually maintenance-free protection from transient voltage spikes and surges, nature has a 
way of occasionally creating electrical forces that are beyond the capabilities of ANY surge suppression device to absorb without some 
degree of damage (such as a direct lightning hit in an outdoor application).  In the rare instance that this occurs, the green “Protection 
OK” LED indicator (located to the right of the retractable light tubes), will not be illuminated.  If this happens, some level of protection 
from voltage surges will remain, but the PL-PRO C’s clamping voltage rating will be compromised and the unit must be returned to Fur-
man for service. 

NOTE:

 Furman’s Classic Series power conditioners do not compensate for high or low AC line voltage. If you frequently move your 

rack to different locations, derive power from generators, use very long extension cords, travel internationally, or are in an area prone 
to brownouts, you may benefit from the use of one of Furman’s AC Voltage Regulators.

MULTI-SEGMENT LED VOLT METER:  

This three-color, 20-LED bar-graph is an accurate, self-checking AC voltmeter that continually measures input AC voltage.  The meter 
reads from 90 to 128 volts in 2 volt increments.  The optimal range voltages are indicated in green, with moderate and extremely high 
or low voltages in yellow and red, respectively.  The voltmeter provides three special flashing patterns to indicate abnormal conditions:

(1)   If only the single left-most (beneath the 90V mark) LED flashes, the input voltage is marginally low. 

(2)   If all of the LED’s on the voltmeter flash, the input voltage is marginally high.  Power to the PL-PRO C’s outlets   will remain unless  
        the incoming voltage rises above the Extreme Voltage Shutdown (EVS) cutoff voltage  (140 volts).
       
(3)   If none of the LED’s on the voltmeter are lit, and the Extreme Voltages LED indicator is illuminated, then the PL-PRO C has shut  
        down power to its outlets because the input voltage is in a range considered extreme (in excess of 140 volts).

USB CHARGER:

The Furman PL-PRO C’s USB charger provides an easy way to recharge many popular electronic accessories as well as cellular com-

Summary of Contents for PL-PRO C

Page 1: ......

Page 2: ......

Page 3: ...ALL CONTENT 2008 FURMAN ALL RIGHTS RESERVED PRINTED IN CHINA ENGLISH Page 4 FRAN AIS Page 10 ESPA OL Page 16 PL PRO C OWNER S MANUAL PL PRO C GUIDE DE L UTILISATEUR PL PRO C MANUAL DEL PROPIETARIO...

Page 4: ...ss through to your equipment when the protection device is subjected to a transient surge or spike While other designs offer clamping voltages that are well above 330 Vpk Furman s SMP clamps at 188 Vp...

Page 5: ...eat 4 The Furman PL PRO C should only be connected to a 120 VAC 50Hz 60Hz 20 amp grounded electrical outlet Do not defeat the ground or change polarization of the power plug 5 Route the AC power cord...

Page 6: ...it will shut off power to the outlets and the Extreme Voltage LED will light NOTE If the mains power is above the high cutoff voltage and has caused the EVS circuit to remove power from the PL PRO C s...

Page 7: ...purchase invoice or receipt showing the purchase date Shipping charges to Furman headquarters must be prepaid by the purchaser of the product Furman shall at its own expense furnish a replacement pro...

Page 8: ...ny other obligation with respect to the products or any part thereof whether based on contract tort strict liability or otherwise Under no circumstances whether based on this Limited Warranty or other...

Page 9: ...PANEL convenience outlet dual pull out lamps wall wart spacing for large transformers bnc lamp connector bnc lamp power switch isolated ac outlet banks 10 ft 12 gauge power cable front lamp dimmer st...

Page 10: ...appels de service et les co teuses minutes de pannes Les circuits de protections traditionnels contre les surtensions doivent tre r par s lorsqu expos s des pointes de tension transitoires impliquant...

Page 11: ...quipement la pluie ou l humidit Le bo tier comporte des niveaux de tensions lev s Ne retirez pas le couvercle Confiez toujours l entretien des techniciens qualifi s Le symbole repr sentant un clair a...

Page 12: ...ire augmenter l imp dance CA comme le font beaucoup de disjoncteurs thermiques moins dispendieux Si la capacit de 20 amp res RMS du PL PRO C est d pass e l interrupteur ressort se mettra automatiqueme...

Page 13: ...popu laires et des appareils de communication cellulaire simplement en branchant le cordon de chargement dans la prise situ e sur le panneau avant Veuillez prendre note qu il y a actuellement plusieu...

Page 14: ...t la date d achat Les frais d envoi doivent tre pay s l avance par l acheteur du produit Furman s engage remplacer le produit ses frais ou selon son jugement r parer le produit d fectueux Les frais d...

Page 15: ...e 0 120 po circuits imprim s sur verre poxyde CONSOMMATION 15 VA LISTE D AGENCE DE S RET TUV gradateur avant de lampe convenance prise de courant deux lampes r tractables indicateur de statut commutat...

Page 16: ...ircuitos supresores de sobretensi n tradicionales se sacrifican cuando se exponen a picos de voltaje m ltiples transitorios que requieren el desmantelamiento de su sistema y la reparaci n del supresor...

Page 17: ...onal calificado El s mbolo de rel mpa go terminado en flecha sirve para alertar sobre la presencia de voltaje peligroso no aislado dentro del gabinete del equipo y puede tener la suficiente magnitud c...

Page 18: ...RMS de 20 amperios del PL PRO C el interruptor con tensi n de resorte cambiar inmediatamente a la posici n de apagado Usted deber colocar el interruptor en la posici n de encendido nuevamente una vez...

Page 19: ...para USB es posible que algunos dispositivos no sean compatibles con nuestro cargador PRESILLAS DE SEGURIDAD PARA ADAPTADORES DE CA TOMACORRIENTES PARA TRANSFORMADORES Su acondicionador Serie Classic...

Page 20: ...proporcionar un producto de reemplazo o bien a su entera discreci n reparar el producto defectuoso Furman pagar los gastos de devoluci n del producto al comprador LA GARANT A ANTERIOR SUSTITUYE A TODA...

Page 21: ...y negro de 0 120 0 32 cm placas de circuito impreso con vidrio epoxi CONSUMO DE ENERG A Aprox 15 VA LISTADO DE LA AGENCIA DE LA SEGURIDAD TUV atenuador de luz tomacorriente para servicio dos l mparas...

Page 22: ...22 PL PRO C OWNER S MANUAL Notes...

Page 23: ...23 FRAN AIS ENGLISH Espa ol Notes...

Page 24: ...1690 Corporate Circle Petaluma California USA 94954 Phone 877 486 4738 Fax 707 763 1310 www FurmanSound com PL PROC_RevA...