circuit.  In fact the bandwidth is less than 0.1dB loss at 1GHz!

To connect your cabling to these in-line protectors, simply follow the 
in and out indications marked next to the Telco, and Cable / Satellite 
connectors.

Note:

It  is  not  possible  to  make  an  in-line  cable  /  satellite  protector 
“maintenance-free.”  Under  extreme  conditions,  it  is  possible  that 
the surge suppression in one of these devices could sacrifi ce itself 
after a catastrophic event.  If the telephone, cable or satellite signal 
will no longer pass through our protector, please send your Power 
Station  to  Furman  for  servicing.    To  test  this,  simply  disconnect 
the  incoming  and  out  going  cable  from  the  PST-6.    Connect  the 
incoming connector to the component that formerly received the out 
going connector, thus by-passing the in-line protection.  If the signal 
is present (but not when used with the PST-6) then the protection 
circuit is damaged (assuming it worked properly before the storm or 
catastrophic event).    
          

Circuit Breaker

If the PST-6 is connected to an AC outlet where suffi cient voltage 
is present, the unit should operate properly with the protection OK 
indicator lit, after the main power switch is turned to the on position.  
If the unit still does not function under these conditions check the 
circuit breaker button!  It is the round black button adjacent to the 
incoming AC cord.  If the circuit breaker trips immediately, there may 
be too great of a current load placed upon it.  Simply disconnect one 

Summary of Contents for PST-6

Page 1: ...The PST 6 Owners Manual...

Page 2: ...y basis At best these irregularities can degrade your equipment s performance at worst they can severely damage individual components or your entire system Not so with Furman With our exclusive Ground...

Page 3: ...The PST 6 should only be connected to a 120 VAC 60Hz 15 amp grounded electrical outlet Do not defeat the ground or change polarization of the power plug 5 Route the power cord and other cables so tha...

Page 4: ...Connectors Telco Satellite Cable Transient Voltage Surge Suppressors The PST 6 features transient voltage surge suppression for both standard telephone lines as well as cable and satellite lines utili...

Page 5: ...nd out going cable from the PST 6 Connect the incoming connector to the component that formerly received the out going connector thus by passing the in line protection If the signal is present but not...

Page 6: ...unit must be returned to Furman Sound or an authorized Furman Service Center for repair Mounting If the Power Station needs to be mounted to the inside panel of a rack or hung from a wall a convenien...

Page 7: ...fects are of such type and nature as to be covered by this warranty Manufacturer shall authorize Purchaser to return the Product to the Furman factory or to an authorized Furman repair location Warran...

Page 8: ...TY IS EXCLUSIVE The sole and exclusive obligation of Manufacturer shall be to repair or replace the defective Product in the manner and for the period provided above Manufacturer shall not have any ot...

Page 9: ...at 707 763 1010 ext 121 between the hours of 8 00 am and 5 00 pm US Paci c Time When returning equipment for repair please use the original packaging to ship the product Also please enclose a note gi...

Page 10: ...10...

Page 11: ...11...

Page 12: ...12 Furman Sound Inc 1997 South McDowell Blvd Petaluma California 94954 6919 USA Phone 707 763 1010 Fax 707 763 1310 Web www FurmanSound com E mail info furmansound com 011104 D...

Reviews: