ABN: 68 606 541 468 Email: info@fandasupplies.com 4
168 Place Cupellation Furnace
240V-FAS-180
Power Requirements
Volts
Phase
Kilowatts
240V
1
1
Fuel Type
LPG
Gas Consumption
280MJ Per Hour
Operating Pressure
140 KPA
Gas Pressure Requirements
Minimum Inlet Pressure
Maximum Inlet Pressure
2.5KPA
140KPA
Safety Devices Installed
UV Flame Detection
System Overview:
This furnace has a fan forced single burner system, with an automatic ignition system.
It can
be swapped between NG and LPG (propane) to suit varying site requirements, with just a
few simple adjustments performed on-site involving a minimum of downtime and
associated costs.
Temperature is monitored and modulated automatically by a Type K thermocouple system and
Omron temperature controller, pre-set for a maximum temperature of 1100 degrees Celsius.
This controller is simple to operate, and has a 2-level display (PV and SV), that shows actual
temperature as well as the temperature the furnace is set to.
The door has a pneumatic ram opening system with an easy to use foot pedal control or
optional hand valve that allows you to open the door part-way so that you can check inside with
minimal temperature loss.