Product Specification
Page 12 of 18
1303090MS01
LA-309 Controlled Atmosphere Infrared Furnace
April 15, 2009
14.8
Additional Customer acceptance tests that are beyond the scope of the original mutually agreed
upon acceptance criteria may be performed at Manufacturer’s facility by Customer
representatives, or by Manufacturer’ personnel, on a time and material basis, to be agreed upon
at the time of order.
15.0 DEFINITIONS
The section describes terms used in this document.
Table 15-1. Definitions
KEY
DESCRIPTION
CDA
Clean, dry air. Compressed air supply that has been filtered of particulate and moisture.
FG
Forming gas, a mixture of H
2
and N
2
gasses usually with 4% H2 or less in the mixture.
H
2
Hydrogen gas; a concentration > 8% in air is considered explosive. For concentrations higher than 4%, FurnacePros
requires inclusion of the Hydrogen Operation (HO) option to safely use hydrogen as a process gas in a furnace.
IO
Input/Output signals as an aggregate. IO is comprised of signals from one or more of these sources: AI (analog
input), AO (analog output), DI (digital input), or DO (digital output).
N
2
Nitrogen gas. Inert. Usually used to displace oxygen from the furnace during processing. The Oxygen Analyzer (OA)
option can be used with our automatic sampling system to continually monitor O
2
(oxygen) levels present in any of 3
zones in a furnace, displaying results on the OI and alerting and alarming when detecting levels above pre-set limits.
PID
Proportional, integral derivative control loop that calculates an output to correct the error between a measured
process temperature and a desired set point temperature.
Summary of Contents for LA-309
Page 5: ...10 004 676 110000 v WARRANTY Warranty goes here ...
Page 6: ...vi LA 309 Owner s Manual ...
Page 12: ...Contents xii LA 309 Owner s Manual ...
Page 20: ...Section 1 1 8 LA 309 Owner s Manual ...
Page 68: ...Section 3 3 28 LA 309 Owner s Manual ...
Page 70: ...Section 4 4 2 LA 309 Owner s Manual ...
Page 72: ...Section 4 4 4 LA 309 Owner s Manual ...
Page 98: ...Section 5 5 2 LA 309 Owner s Manual ...
Page 100: ...Section 5 5 4 LA 309 Owner s Manual ...
Page 106: ...Section 5 5 10 LA 309 Owner s Manual ...
Page 108: ...Section 5 5 12 LA 309 Owner s Manual ...
Page 110: ...Section 5 5 14 LA 309 Owner s Manual ...
Page 112: ...Section 6 6 2 LA 309 Owner s Manual ...
Page 114: ......
Page 115: ......
Page 126: ...Section 7 1 Fiberfrax Cements MSDS 042006 Owner s Manual ...
Page 139: ...MSDS 2 Fiberfrax Duraboard MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Page 140: ...Section 7 2 Fiberfrax Duraboard MSDS 042006 Owner s Manual ...
Page 153: ...MSDS 3 Fiberfrax Fibers MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Page 154: ...Section 7 3 Fiberfrax Fibers MSDS 042006 Owner s Manual ...
Page 167: ...MSDS 4 Fiberfrax Papers MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Page 168: ...Section 7 4 Fiberfrax Papers MSDS 042006 Owner s Manual ...
Page 181: ...MSDS 5 Magnaform MSDS 050406 MATERIAL SAFETY DATA SHEETS ...
Page 182: ...Section 7 5 Magnaform MSDS 050406 Owner s Manual ...
Page 183: ......
Page 184: ......
Page 185: ...Section 7 6 RTU Silicone Red Hi Temp 042006 Owner s Manual ...
Page 186: ...MSDS 6 RTU Silicone Red Hi Temp 042006 MATERIAL SAFETY DATA SHEETS ...
Page 189: ...Section 7 7 Kaowool Insulation MSDS 050406 Owner s Manual ...
Page 190: ...MSDS 7 Kaowool Insulation MSDS 050406 MATERIAL SAFETY DATA SHEETS ...
Page 201: ...Material Safety Data Sheets 7 15 Notes ...
Page 202: ...Section 7 7 16 Owner s Manual ...
Page 204: ...Section 8 Owner s Manual ...
Page 206: ...Section 8 Owner s Manual ...
Page 212: ...iv Operation and Troubleshooting ...
Page 214: ...vi Operation and Troubleshooting ...
Page 224: ...Page 10 Operation and Troubleshooting ...
Page 231: ...9 1 Section 9 APPENDIX B 9 1 EC913 CALIBRATION REPORT 9 2 SERIES EC900 OXYGEN ANALYZERS ...
Page 232: ...Section 8 Owner s Manual ...
Page 233: ......
Page 234: ...Section 8 Owner s Manual ...
Page 279: ...Section 8 Owner s Manual ...
Page 281: ...MSDS MATERIAL SAFETY DATA SHEETS ...
Page 282: ...16 Notes ...