14
Specification
Specifications
Total Capacity
15.6 cu. ft. (442L)
Freezer Capacity
6.08 cu. ft. (172L)
Fridge Capacity
9.54 cu. ft. (270L)
Noise (dB)
≤42dB
Door Type
Side by Side
Handle
Recessed Handle
Control Type
LED Display with electronic control
No. of Shelves
6
No. of Crisper
4
Cooling Type
Compression cooling system
Specifications
Refrigerant
R600a
Rated Voltage
DC 12V
Rated Current
19A (
≤
20A)
Power Consumption
667kWh/year
Off-Grid Rating
5.3Ah @ 77
°F
(25
°C
)
Temperature Range
Refrigerator: 32°F to 43°F (0°C to 6°C) adjustable
Freezer: -10°F to 5°F (-23°C to -15°C) adjustable
Working Temperature
Range
50°F to 110°F (10°C to 43°C)
Defrost
Automatic
Certification
CSA
Troubleshooting
Before contacting the Furrion Customer Service:
1. Try to solve the problem yourself following the points described in the table below.
2. Turn off the appliance and restart it to see if the fault persists.
Trouble
Possible Cause
Solution
No display on the
display panel
Appliance is not switched on
Switch on the appliance.
RV batteries are empty.
Recharge the DC12V power source (by connecting RV to the shore
power).
Fuse is blown or defective
Check fuse, replace if necessary.
DC connecting wires are intermittent / broken
Such malfunctions are to be corrected by an electrician.
Alarm sound
Door is slightly open or not closed fore more than 1 minute
Close the door completely.
Compressor doesn’t
work
Under defrosting mode
Normal for defrosting.
DC12V power source voltage is too low or DC12V
power source is too weak.
Charge / replace DC12V power source.
Vibrating noise
Floor is uneven or week
Be sure the floor is even and solid and can adequately support the fridge.
Items placed on the top of the fridge are vibrating
Remove items.
Fridge touches the wall or cabinet
Move fridge so that it does not touch the wall or cabinet.
Layer of Frost in
compartment
Blocked air outlets
Check air outlets not blocked, ensure food placed in appliance has
sufficient ventilation
Doors can’t be
closed easily
Blockage
• Check nothing internal is trapped in the door.
• Tilt the refrigerator back to allow self-closing mechanism
Light is not working
Damaged LED
Contact Manufacturer
Control system disabled lights
If door has been left open too long lights will be deactivated. Close &
reopen the door to activate