Programming Guide
8-9
8.3. History
By selecting “History” in the Menu screen, the operator can access details of the splice data, arc check history
and image archives; user can also add comments to each individual data. The data also can be transferred/
uploaded to PC or deleted from the memory.
1. In the Menu screen, select the
“History” and press Enter key.
2. Select
“Splice Data”, “Arc Check History” or “Image Data” and press Enter key to get the stored data.
8.3.1.
Splice Data
1.
If “Splice Data” is selected, a list of previous splice data is displayed on the screen (as shown in the picture
below).
2. Select a targeted date and press Enter key to obtain the detail of the data as shown in the picture.
As for the history with
“
*
”, the splice image is preserved automatically.
The data structure displayed are as follows;
Data Title
Description
CMNT
Comment of the data, which can be edited.
No.
No. 1 is the data for the last splice and the number increases for
older splices.
Arc Count
Arc Count when splice was performed.
Date
Date and time for the splice performed.
PRGM
Name of Fusion Program.
W.L.
Wavelength
Arc Power
Value of Arc Power
AngL:
Cleave angle of the left fiber.
AngR:
Cleave angle of the right fiber.
AngT:
Relative cleave angle between left and right fibers.
Loss:
Estimated splice loss.
Note:
Error codes and additional arc memo if any. The data with error is
highlighted.
L: Estimated loss exceeds the target value
S: Streak or bubble at the splice point or not spliced
A: Cleave angle exceeds the criteria
C: Cleave end face has excessive defects
+: Additional arc is applied