11
2. WIRING
The MFDBB, MFD8, MFD12, PSU-012 or PSU-017 connects to the radar sensor with the two-way
cable MOD-ASW0001 (MOD-ASW0002 for DRS25A). In order to minimize the chance of picking
up electrical interference, avoid where possible routing the two-way cable near other onboard
electrical equipment. After passing the cable through the hole in the radar sensor, apply sealing
compound around the hole for waterproofing. When connecting to other NMEA2000 equipment,
use the optional cable M12-05BFFM
(φ
6) or CB-05BFFM (
φ
10).
Note:
When TZT9/14/BB is connected to the radar sensor, confirm that the program ver-
sion of the radar sensor is 0359235-01.16 or higher.
Wiring for DRS2D/4D/4A/6A/12A without PSU-012
NOTICE
Before connecting or disconnecting the
NMEA2000 cable, turn off the radar sensor.
The sensor may become damaged if the power is
not turned off.
RADAR SENSOR
DRS4A/DRS6A/DRS12A
NMEA2000
Eq
u
ipment
: Standard S
u
pply
: Optional S
u
pply
NMEA2000
Eq
u
ipment
RADAR SENSOR
DRS2D/DRS4D
To
M
u
lti F
u
nction Display BlackBox
MFDBB or M
u
lti F
u
nction Display
MFD8/12
Two-way cable
MOD-ASW0001
(10/15/20/30 m)
NMEA2000 cable
M12-05BFFM (
φ
6) or
CB-05BFFM (
φ
10)
NMEA2000 cable
M12-05BFFM (
φ
6) or
CB-05BFFM (
φ
10)
Summary of Contents for DRS12ACM