17
2.3 Optional 50 kHz and 200 kHz Transducers
To connect optional transducer 50B-6, 50B-6B, 50B-6G, 50B-62M, 50B-9B, 50B-92M,
200B-5, 200B-5S, 50/200-1T or 50/200-12M, the optional Distribution Box (MB-1000, code
no. 000-040-809) is required. Additionally, a cable assembly (02S4089, code no.
000-133-622) is required to connect to the network sounder. Fasten the cable from the
Distribution Box to the XDR connector on the network sounder.
To network sounder
(cable is fitted with
8P connector.
8P-10P converter
connector is re-
quired.)
Shield
TRANSDUCER
50B-6/6B/6G
50B-62M
50B-9B
50B-92M
200B-5/5S
50kHz
200kHz
SHIELD
RED
RED
BLK
BLK
TB2
1
2
3
4
5
J2 J1
BLK
3
2
1
WHT
TB1
02P6168
Jumper block setting
J2: Full power output
J1: Reduced output
(SHIELD)
(RED)
(BLU)
(GRN)
(BLK)
TB2
1
2
3
4
5
1
2
3
TB1
50/200-1T
or
50/200-12M
(SHIELD)
(BLK)
(WHT)
Figure 2-6 Distributor MB-1000
Distribution Box (Type: MB-1000, Code No.: 000-040-809)
Name Type
Code
No.
Qty
Remarks
Distribution
Box
MB-1000 000-040-805
1
Cable w/8P connector supplied for
connection to network sounder
Crimp-on Lug
FV1.25-3 Red 000-538-113
6
Cord Lock
NC-1
000-516-650
1
For use with separate transducer
Fabrication of transducer cable
Fabricate the transducer cable as illustrated below to connect it to the Distribution Box.
Crimp-on lug
FV1.25-3, Red
Clamp here.
Tape
Vinyl Sheath
Vinyl Tube
Shield
Figure 2-7 Fabrication of transducer cable