18
3. INITIAL SETTINGS
WARNING
ELECTRICAL SHOCK HAZARD
Do not open the equipment
unless totally familiar with
electrical circuits and
service manual.
Only qualified personnel
should work inside the
equipment.
3.1 Selecting the Transmission Power
The default transmission power is 600 W. If you install the 1 kW transducer, change the
jumper connector to #3-4 from #1-2 on J12 as follows:.
1. Detach the power cable from the connector.
2. Open the cover of the ETR-6/10N.
3. Remove the jumper connector on J12 by using long-nose pliers.
4. Insert it to #3-4 pins of the J12 for 1 kW transducer.
Note: Do not insert the jumper connector upside down.
5. Close the cover.
Figure 3-1 Location of parts inside ETR-6/10N
J800
NET
03P9284
J6
J3
J2
J1
J12
Fuse (4A)
1-2
3-4
J12
#1-2: for 600 W (Default)
#3-4: for 1 kW
02P6294