1. RADAR OPERATION
1-66
9. Select 3 ANT HEIGHT.
10. Select appropriate radar antenna height (above the waterline).
11. If necessary, open the menu, select the ECHO menu and 9 STC RANGE to
adjust effective STC range. The setting range is –10 to +10. The larger the
number the longer the effective STC range becomes. Roll the scrollwheel to
set. (Note that the keyboard cannot be used to enter the setting.)
12. If necessary Select 4 LOW LEVEL ECHO to reject low level echoes. The
setting range is 0-8. The higher the figure the stronger the low level echo that
is erased.
13.
To save a program,
Select 0 DEFAULT.
14. Select SAVE and push the scrollwheel or left button.
15. Push the right button twice to close the menu.
Note:
You may also program and save other picture setups.
1.35.3 Restoring
user
settings
If you get lost in operation while adjusting the settings for a picture setup, you
can easily restore user settings for that picture setup. Note that user settings are
deleted when default settings are restored.
1. Left-click the PICTURE box at the left side of the screen to select the picture
setup option for which you want to restore its user settings.
2. Push the right button to show the PICTURE menu.
3. Select 0 DEFAULT.
4. Select USER and push the left button or scrollwheel.
5. Push the right button to close the menu.
1.35.4
Restoring default picture setup options
Any of the radar functions programmed with the picture setup options may be
adjusted as desired. If you get lost in operation and want to restore the default
settings for a particular picture setup operation, do the following:
1. Left-click the PICTURE box at the left side of the screen to select the picture
setup option for which you want to restore its default settings.
2. Push the right button to show the PICTURE menu.
3. Select 0 DEFAULT.
4. Select FACTORY and push the left button or scrollwheel.
5. Push the right button to close the menu.