2. WIRING
2-4
5. Fold back armor and pass the flat washer as shown in the figure below. Cut and
trim the armor around the flat washer.
Passing clamping gland, washer and gasket on the signal cable
6. Confirm that armor is grounded between two flat washers.
7. Coat the screw part of the clamping gland with silicone sealant and tighten it.
8. Use the opener, and insert each core (except coaxial cable) to appropriate con-
nector plug on the TB801.
9. Loosen two screws and slide the TB board assembly upward and pull it out.
Gasket
Vinyl sheath
Clamping gland
Flat washer
Cut and trim armor.
Grounding point for the shield.
Pass the signal
cable RW-9600.
TB801
TB801
TB802
Clamp shield of
coaxial cable.
TB board
Coaxial cable