49
Environment
Ambient Temperature
0 to +40°C
(Operating)
+5 to +30°C
(Operating) (Recommended)
-10 to +60°C
(Storage)
Humidity
20 to 85%RH
(Without condensing) (Operating)
20 to 85%RH
(Without condensing) (Storage)
Once that condensed, performance can not be assured even if the battery charger
is dried.
Vibration
19.6 m/s
²
(10 to 55 Hz)
Mechanical Shock
Withstands one time of free fall from 75 cm height. (No hazard)
Dusts
General shops or warehouses for logistics
Corrosive Gas
General shops or warehouses for logistics
Insulation Resistance
10 M ohms or more (500 VDC)
Dielectric Strength
1500 VAC (1 minute)
Compliance
IEC60950
NOTE: The above-listed data are not guaranteed values but the ones obtained by factory
test.
The above-listed data may not be obtainable locally if test is performed in the
environment (test facilities etc.) different from the factory.