2. WIRING
2-8
How to fabricate cables connected to the FRP_TB board
(03P9548)
Signal cable RW-0013
TTYCSLA cables
Cable lengths of L1, L2 and L3 (mm)
Connector No.
Cable type
L1
L2
L3
J612 (NMEA1)
TTYCSLA-1T
120
60
80
J613 (NMEA2)
TTYCSLA-4
200
60
150
J614 (NMEA3)
TTYCSLA-1
120
60
100
J615 (NMEA4)
TTYCSLA-1
60
100
120
J616 (NMEA5)
TTYCSLA-4
250
80
200
J617 (NMEA6)
TTYCSLA-4
230
80
200
J619 (ROT/RUDDER)
TTYCSLA-7
200
60
120
Vinyl sheath
240
Wind the inner shield around the outer shield.
Vinyl tape
Set this part in the cable clamp.
Connect to WAGO connector.
Coaxial cable
8
15 515
Conductor
Fold back shield.
Inner shield
100
(Fold back outer shield over the vinyl sheath.)
Pull out wires from the inner shield.
L1 to 3: See the table shown on next page.
Pass the vinyl tape (local suppy) onto the drain wire. Attach a
crimp-on lug (preattached to the processor unit) to the drain wire.
Fasten the crimp-on lug to its original location.
Sheath
Drain wire
Crimp-on lug
8
5
L1
Armor
L2
Vinyl tape
Secure tape with
cable tie (supplied).
Set this part in cable clamp.
L3
Summary of Contents for FR-1908V-BB
Page 2: ...Installation Manual This page is intentionally left blank...
Page 6: ...EQUIPMENT LISTS iv This page is intentionally left blank...
Page 14: ...1 MOUNTING 1 8 This page is intentionally left blank...
Page 30: ...3 ADJUSTMENTS 3 8 This page is intentionally left blank...
Page 40: ...11 Dec 2018 H MAKI D 1...
Page 41: ...D 2 2 Nov 2017 H MAKI...
Page 42: ...D 3 2 Nov 2017 H MAKI...