4-4
Setting method 1: DIP switch settings and gyrocompass specifications
1) Gyrocompass type 2) Frequency
Gyrocompass
type
SW
1-4
SW
1-5
SW
1-6
JP1
Frequency
SW
1-7
SW
1-8
Remarks
AC
synchronous
OFF
OFF
OFF
#1, #2,
#3
50/60 Hz
OFF
OFF
AC synchronous
pulsating current
DC
synchronous
OFF
OFF
OFF
#2, #3,
#4
400 Hz
ON
OFF
AC synchronous
pulsating current
DC step
ON
OFF
OFF
#4, #5,
#6
500 Hz
OFF
ON
AC synchronous
pulsating current
Full-wave
pulsating current
OFF
ON
0FF
#4, #5,
#6
DC
ON
ON
DC synchronous
DC step
Half-wave
pulsating current
ON,
ON
OFF
#4, #5,
#6
3) Rotor Voltage (between R1 & R2) 4) Stator Voltage (between S1 & S2)
Rotor Voltage
SW
2-1
JP3
Stator
Voltage
SW
2-2
SW
2-3
JP2
20 to 45 VAC
ON
#2
20 to 45 VAC, or
20 to 60 VDC
OFF
OFF
#2
30 to 70 VAC
OFF
#2
30 to 70 VAC, or
40 to 100 VDC
ON
OFF
#2
40 to 90 VAC
ON
#1
40 to 90 VAC
OFF
ON
#1
60 to 135 VAC
OFF
#1
60 to 135 VAC
ON
ON
#1
5) Ratio 6) Supply Voltage
Ratio
SW
1-1
SW
1-2
SW
1-3
Stator
Voltage
SW
2-2
SW
2-3
JP2
360X
OFF
OFF
OFF
20 to 45 VAC, or
20 to 60 VDC
OFF
OFF
#2
180X
ON
OFF
OFF
30 to 70 VAC, or
40 to 100 VDC
ON
OFF
#2
90X
OFF
ON
OFF
40 to 90 VAC
OFF
ON
#1
36X
OFF
ON
OFF
60 to 135 VAC
ON
ON
#1
7) AD-10 format data Tx interval 8) NMEA interval
Tx Interval
SW2-4
Select data transmitting interval for ports 1 to 6 with jumper
wires JP6 and JP7. The Tx interval is available in 25 ms or
200 ms. 25 ms is for radar: 200 ms is for all other equipment.
2 seconds
ON
1second
OFF
Summary of Contents for FR-2115-B
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ......
Page 86: ......
Page 87: ......
Page 88: ......
Page 89: ......