8. MAINTENANCE, TROUBLESHOOTING
8-13
8.12.2
How to raise the transducer manually
1.
Open the lid on the raise/lower control box of the hull unit and turn off the motor
breaker. Confirm that the power lamp is off. (See the illustration on the preceding
page for the location of the motor breaker and power lamp.)
2.
Unscrew two screws (see the figure at step 3.) to remove the cover.
3.
Attach the crank to the motor shaft, referring to the illustration below.
4.
While holding the crank, pull the release lever toward you and upward to release
the brake.
Note:
Hold the crank when releasing the brake, to prevent the transducer from
falling out.
Screw
Crank
Motor
Cover
Release lever
Holder