2. WIRING
2-14
DPYCYS-2.5 cable
Fabricate the cable as shown in the following figure.
2.5.2
Input Voltage and Fuses
The transceiver unit is shipped from the factory with its input voltage set for 230 VAC
and a 10 A fuse inserted in F601 and F602. For other voltages, change toggle switch
positions and fuses as shown below.
Input voltage and toggle switch
Fuses
Change the fuse in F601 and F602 according to input voltage, referring to the table
below.
Input voltage
S603
S604
S605
Default
setting
100 VAC
L
L
L
-
110 VAC
H
L
L
-
115 VAC
H
H
L
-
220 VAC
H
L
H
-
230 VAC
H
H
H
Default
Input Voltage (TB-B101)
F601
F602
Default
setting
100 VAC
20A
20A
-
110 VAC
-
115 VAC
-
220 VAC
10A
10A
-
230 VAC
Default
Anti-corrosive
sheath
140 mm
140 mm
30 mm
30 mm
35 mm
35 mm
vinyl sheath
Set armor in cable clamp
Crimp-on lug FV2-4
(2 pcs. )
WARNING
Use the correct fuse.
Use of a wrong fuse can result in
damage to the equipment.
Summary of Contents for FSV-85-MARK-2
Page 34: ...1 HOW TO INSTALL THE SYSTEM 1 26 This page is intentionally left blank ...
Page 58: ...2 WIRING 2 24 This page is intentionally left blank ...
Page 86: ...D 1 7 Jul 2021 H MAKI ...
Page 87: ...D 2 7 Jul 2021 H MAKI ...
Page 88: ...D 3 7 Jul 2021 H MAKI ...
Page 89: ...D 4 7 Jul 2021 H MAKI ...
Page 90: ...D 5 7 Jul 2021 H MAKI ...
Page 91: ...D 6 7 Jul 2021 H MAKI ...
Page 92: ...22 Apr 2014 H MAKI D 7 ...
Page 93: ...D 8 24 Jun 2021 H MAKI ...
Page 94: ...D 9 24 Mar 2021 H MAKI ...
Page 95: ...D 10 24 Jun 2021 H MAKI ...
Page 96: ...D 11 24 Jun 2021 H MAKI ...
Page 98: ...D 13 17 Feb 2021 H MAKI ...
Page 99: ...28 Apr 2018 H MAKI D 14 ...
Page 100: ...D 15 13 Sep 2011 Y NISHIYAMA ...
Page 101: ...D 16 13 Sep 2011 Y NISHIYAMA ...
Page 102: ...D 17 13 Sep 2011 Y NISHIYAMA ...