FURUNO
FSV-85
SP - 2
E1335S01E-M
4 HULL
UNIT
Motion sensor
Travel (mm)
attached blank
Raise/lower
time (sec)
Ship’s speed allowance
(at R/L operation)
500/800 FSV-8x31/32
FSV-8x33/34
21
800/1100
FSV-8x41/42 FSV-8x43/44
28
18 kn
(
15 kn
)
x: 4 or 5. FSV-8431 series for 80kHz, FSV-8531 series for 70kHz.
5 INTERFACE
5.1 CIF input sentences
System clock, Position, Bearing, First layer current data,
Water depth, Water temperature, Sonde depth,
Ship’s speed/course data, Multi-layer current data, Net depth,
Wind speed/direction, Sonde number
5.2 NMEA0183
Input sentences
CUR, DBS, DBT, DPT, GGA, GLL, GNS, HDG, HDM, HDT, MDA,
MTW, MWV, RMA, RMC, VBW, VDR, VHW, VTG, VWR, VWT, ZDA
Output sentence
TLL
6 POWER
SUPPLY
6.1 Processor unit
12-24 VDC: 10-5 A
6.2 Interface unit
48 VDC: 1 A or less
6.3 Transceiver
unit
100/110/115/220/230 VAC: 15 A, 1 phase, 50/60Hz
6.4 Hull unit
200-220 VAC: 4 A, 3 phase, 50/60Hz
6.5 Rectifier (RU-1746B, option) 100-115/220-230 VAC, 1 phase, 50/60Hz
7 ENVIRONMENTAL
CONDITION
7.1 Ambient
temperature
Processor unit
0°C to +45°C
Transducer
-5°C to +35°C
Others
0°C to +50°C
7.2 Relative humidity
93% max. at 40°C
7.3 Degree of protection
Control unit
IP22 (panel), IP20 (chassis)
Interface unit
IP20
Transducer IPX8
Transceiver unit, others IPX0
7.4 Vibration
IEC 60945 Ed.4
8 COATING
COLOR
8.1 Control unit
Chassis: N2.5, Key pad: N1.0
8.2 Processor/ Interface unit N2.5
8.3 Transceiver/ Hull unit
2.5G7/2
Summary of Contents for FSV-85
Page 1: ...COLOR SCANNING SONAR FSV 85 OPERATOR S MANUAL www furuno com Model ...
Page 128: ...5 NUMERIC GRAPHIC DATA DISPLAY 5 4 This page is intentionally left blank ...
Page 158: ...8 RECORD RECALL OPERATION 8 8 This page is intentionally left blank ...
Page 172: ...9 MAINTENANCE TROUBLESHOOTING 9 14 This page is intentionally left blank ...
Page 178: ...APPENDIX 1 MENU TREE AP 6 This page is intentionally left blank ...
Page 184: ......