7. OTHERS MENU
7-14
7.6.7
Net SONDE Setting menu
The [Net SONDE Setting] menu sets up the net sonde. Select [Net SONDE Setting]
on [Initial Setting] then push the left-click button.
Number Of XMTR
: Sets number of transmitter units used, from 0-10. When the total
value of [XMTR Distance] is smaller than the setting value of [Net Length], max. 10
transmitter units can be used.
XMTR Distance
: Sets the distance between transmitters. Select this item then push
the left-click button to set the distances.
Net Length
: Sets net length in increments of 100 m. Setting range is 1200 m* to 3000
m.
*: The minimum setting range for net length varies, depending on the settings for
[Number of XMTR] and [XMTR Distance].
Depth Display
: Selects which sonde depth data to show. Select this
item and push the left-click button to select net sondes. The check
mark shows current selection (Max. 3).
Display Style
: Selects the display format of the net depth, Numeric
or Graph.
Depth Graph Range
: Sets the depth range of SONDE graph. The
setting range is 50 m, 100 m, 150 m, 200.
*Setting cannot be adjusted after the net is thrown.
*
*