List of ADU events
B-4
0A02B-0 Antenna ERROR
ABS software
version
The ABS software version in the antenna is too
old to match the hardware requirements.
Upgrade the software.
0A02D-0 Antenna ERROR
BUC reference
switch
The BUC reference switches do not work.
Check PCM-VIM cable and replace cable,
VIM or PCM.
0A034-0 Antenna WARNING ACU
communication
The communication link between ACU and
antenna is down.
0A035-0 Antenna WARNING ISM data valid
Sensor measurements from the ISM are
invalid. This indicates a malfunctioning ISM.
0A036-0 Antenna WARNING ISM data range
Sensor measurements from the ISM are out of
range.
0A037-0 Antenna WARNING GNSS
communication
Lost connection to the GNSS device.
0A038-0 Antenna WARNING GNSS data
range
Received information from the GNSS device
which is out of range.
0A039-0 Antenna WARNING GNSS device
warning
Local GNSS device warning.
0A03A-0 Antenna WARNING GNSS device
error
Local GNSS device error.
0A03B-0 Antenna ERROR
Azi DDM
shutdown
The azimuth motor control has detected one of
the following situations: Extreme temperature,
voltage, current or velocity. The motor was
then shut down. This is usually a temporary
situation and is probably fixed by a restart of
the system.
0A03C-0 Antenna ERROR
Xel DDM
shutdown
As Azi DDM shutdown but detected by the
cross-elevation motor control.
0A03D-0 Antenna ERROR
Ele DDM
shutdown
As Azi DDM shutdown but detected by the
elevation motor control.
0A03E-0 Antenna ERROR
PMM shutdown As Azi DDM shutdown but detected by the
polarisation motor control.
0A03F-0 Antenna WARNING AMB timing
This indicates a busy situation. It may occur
during installation procedures. No user
interaction is required.
Error
code (ID)
Unit
Severity
Description
Explanation
Table B-1: ADU event messages (Continued)
Summary of Contents for FV-110GX
Page 1: ...GX TERMINAL FV 110GX OPERATOR S MANUAL www furuno com Model ...
Page 16: ...xiv This page is intentionally left blank ...
Page 46: ...Installation of the ADU 2 22 N connector interface on the ADU ...
Page 54: ...To connect the ADU ACU and GMU 2 30 This page is intentionally left blank ...
Page 110: ...Installation check list Functional test in harbor 6 4 This page is intentionally left blank ...
Page 164: ...Supported commands C 10 This page is intentionally left blank ...
Page 165: ...D 1 Appendix D Approvals D This appendix lists the approvals for FV 110GX OEM declaration ...
Page 166: ...OEM declaration D 2 D 1 OEM declaration ...
Page 173: ...OD 1 30 Jul 2018 H MAKI ...
Page 174: ...OD 2 30 Jul 2018 H MAKI ...
Page 175: ...OD 3 2 Oct 2018 H MAKI ...
Page 176: ...OD 4 2 Oct 2018 H MAKI ...
Page 178: ......
Page 186: ......