List of ACU events
B-11
08840-0 ADM WARNING Master PLL lock
The master PLL has lost lock. Check the input
reference signal.
08841-0 ADM ERROR
Tuner lock
The internal tuner PLL was unable to lock.
08842-0 ADM WARNING GSC demodulator
The GSC demodulator has reported an error.
08843-0 ADM WARNING DVBS demodulator The DVBS demodulator cannot be initialised and
loaded correctly.
08844-0 ADM WARNING BUC voltage
The BUC voltage is out of range.
08845-0 ADM WARNING LNB voltage
The LNB voltage is out of range. The LNB
might be switched off to protect the power
supply circuitry. Reactivate satellite profile to try
again, check LNB cable and surroundings if the
problem persists.
08880-0 ADM ERROR
WLAN
configuration error
Configuration of WLAN module failed.
08A00-0 ADM WARNING GX Core Module
fan
There is a problem with the Core Module fan.
Check/clean and replace if necessary.
08A01-0 ADM WARNING GX Core Module
heater
There is a problem with the Core Module heater.
Check and replace if necessary.
08A02-0 ADM WARNING GX Core Module
temperature
The Core Module temperature is out of range.
This may affect performance, and the Core
Module will be shut down if the situation gets
worse. If the "GX core module heating" event is
also present, the internal heater is currently
warming up the unit to its operational
temperature.
08A03-0 ADM ERROR
GX Core Module
The Power Good signal from the Core Module is
low. Check cables.
08A04-0 ADM WARNING iDirect modem
The ACU detected a warning/error in the iDirect
modem. Log into the modem for more
information.
Info: 0x00000001: Temperature error
0x00000002: Test error 0x00000004: Fan error
08A05-0 ADM WARNING GX Core Module
heating
The GX core module heater is active. It will
automatically be cleared when the core module
reaches the operational temperature level.
Error
code
(ID)
ACU
PCB
Severity
Description
Explanation
Table B-2: ACU event messages (Continued)
Summary of Contents for FV-110GX
Page 1: ...GX TERMINAL FV 110GX OPERATOR S MANUAL www furuno com Model ...
Page 16: ...xiv This page is intentionally left blank ...
Page 46: ...Installation of the ADU 2 22 N connector interface on the ADU ...
Page 54: ...To connect the ADU ACU and GMU 2 30 This page is intentionally left blank ...
Page 110: ...Installation check list Functional test in harbor 6 4 This page is intentionally left blank ...
Page 164: ...Supported commands C 10 This page is intentionally left blank ...
Page 165: ...D 1 Appendix D Approvals D This appendix lists the approvals for FV 110GX OEM declaration ...
Page 166: ...OEM declaration D 2 D 1 OEM declaration ...
Page 173: ...OD 1 30 Jul 2018 H MAKI ...
Page 174: ...OD 2 30 Jul 2018 H MAKI ...
Page 175: ...OD 3 2 Oct 2018 H MAKI ...
Page 176: ...OD 4 2 Oct 2018 H MAKI ...
Page 178: ......
Page 186: ......