Calibration
5-12
5.3.4
Manual One Touch Commissioning (BUC calibration)
When the modem starts up for the first time it will automatically register with the BUC
and perform P1dB compression on multiple frequencies and thereafter register with the
Inmarsat network. During the P1dB compression the antenna will point away from the
satellite and transmit on 950 MHz to 1950 MHz in 50 MHz steps. The ACU will show
BUC calibration
on the
DASHBOARD
and the ACU display. This may take up to 10
minutes.
If a new cable calibration is made, the ACU displays the alarm
BUC calibration
outdated
. Then you must make a manual One Touch Commissioning.
To make a manual One Touch Commissioning (OTC) for the modem, do as follows:
1. Connect a PC to LAN1.
2. Enter the web interface (via Firefox browser) and go to
SERVICE > Modem
.
Figure 5-10: Web interface: SERVICE > Modem
3. At
Modem access
click the link.
WARNING!
For your safety: Active RF transmission may occur during an
OTC procedure. Software updates may also occur, yet the system is in
receive-only mode during such auto-updates.
Important
You must use the Internet browser
Firefox
.
Summary of Contents for FV-110GX
Page 1: ...GX TERMINAL FV 110GX OPERATOR S MANUAL www furuno com Model ...
Page 16: ...xiv This page is intentionally left blank ...
Page 46: ...Installation of the ADU 2 22 N connector interface on the ADU ...
Page 54: ...To connect the ADU ACU and GMU 2 30 This page is intentionally left blank ...
Page 110: ...Installation check list Functional test in harbor 6 4 This page is intentionally left blank ...
Page 164: ...Supported commands C 10 This page is intentionally left blank ...
Page 165: ...D 1 Appendix D Approvals D This appendix lists the approvals for FV 110GX OEM declaration ...
Page 166: ...OEM declaration D 2 D 1 OEM declaration ...
Page 173: ...OD 1 30 Jul 2018 H MAKI ...
Page 174: ...OD 2 30 Jul 2018 H MAKI ...
Page 175: ...OD 3 2 Oct 2018 H MAKI ...
Page 176: ...OD 4 2 Oct 2018 H MAKI ...
Page 178: ......
Page 186: ......