SP - 2
E4429S00D
4 INTERFACE
4.1
Input data sentences IEC61162-1 and NMEA 0183 Ver2.0
DBT, DPT, MTW, TLL*, VHW, HDT, HDG, DSC*, MWV, DSE*, GGA,
GLL, RMA, RMC, VTG, ZDA
*: Output with Ver3.0 format.
4.2
Output data sentences IEC61162-1 or NMEA 0183 Ver2.0 selected on menu
$GPAAM,
$GPAPB
*2
, $GPBOD, $GPBWR
*2
, $GPGLL
*2
,
$GPGTD
*1
, $GPHDG, $GPGGA, $GPRMA
*2
, $GPRMB
*2
, $GPRMC
*2
,
$GPVTG
*2
, $GPXTE
*2
, $GPZDA, $GPWPL, $GPMWV, $GPVHW,
$GPTLL
*4
, $GPRTE, $GPMTW, $GPDBT, $GPDPT
*3
, $GPHSC,
$GPWCV
*2
, $GPAPA
*1
*1
:
Not recommended at Ver2.0 (with Checksum)
*2
: Output with Ver2.0 format (w/o Mode indicator added Ver3.0)
*3
: Output with Ver3.0 format (w/o Maximum range scale in use
added Ver3.0)
*4
: Output with Ver3.0
5 SOUNDER
5.1
Transmit Frequency
50 and 200 kHz, dual frequency
5.2
Transmission
600 Wrms or 1 kWrms
5.3 Display
range
5/10/20/40/80/150/300/500 m, shift; 0-1200 m
15/30/60/120/200/400/1000/1500 ft, shift; 0-4000 ft
5.4
Extension Mode
Marker zoom, Bottom zoom, Bottom rock, Bottom descrimination
5.5
Auto Mode
Cruising/Fishing selected
5.6
Picture advance
6 steps
6 POWER
SUPPLY
6.1
Display Unit
12-24 VDC: 1.5-0.8 A
7 ENVIRONMENTAL
CONDITION
7.1
Ambient Temperature
Antenna Unit: -20°C to +70°C
Display Unit: -15°C to +55°C
7.2
Relative Humidity
95% or less at 40°C
7.3
Water proofing
Antenna Unit: IP46
(IEC60529) Display
Unit:
IP45
7.4 Vibration
• 2 - 5 Hz and up to 13.2 Hz with an excursion of
±
1 mm
±
10%
(IEC 60945)
(7 m/s² maximum acceleration at 13.2 Hz)
• 13.2 - 100 Hz with a constant maximum acceleration of 7 m/s²
www.reelschematic.com