7
Attach the crimp-on lug (FV2-4 BLU, supplied) to the ground wire (IV-2sq., local supply), then fix it to the ground
terminal.
Connect the external equipment to the MC-3000S-N, using the TTYCSLA and FR-FTPC-CY cables.
1.
Fabricate the TTYCSLA and FR-FTPC-CY cables as shown below.
TTYCSLA cable
FR-FTPC-CY cable
2.
Unfasten seven binding screws (M4×10) to remove the junction box cover.
Grounding
7
Ground wire
Ground wire
Ground
terminal
Ground
terminal
Wiring for MC-3000S-N
8
6 mm
60 mm
Pass the heat shrink tubing (local supply)
onto the drain wire, then attach the crimp-on
lug (FV1.25-4 (LF) RED, supplied) to it.
Crimp-on lug
Drain wire
Drain wire
Aluminum tape
600 mm
5 mm
Crimp the rod terminals (AI 0,75-6
GY, supplied), using the crimping
tool (CRIMPFOX 10S). After crimp-
ing, confirm that the 0.5 to 1 mm of
the wires are exposed.
Armor
Sheath
Sheath
Vinyl tape (Width: 20 mm)
0.5 to 1 mm
500 mm
Inner sheath
Cable jacket
LAN connector