1. INSTALLATION
1-20
1.5.2
Choosing processor unit mounting method and direction and
measuring distances between antennas
1. Turn on the processor unit and then press the
MENU
key to show the menu.
MAIN MENU
SATELLITE
WAAS/DGPS
I/O SETUP
INST MENU
ERASE
TRIP MENU
ALARMS
MESSAGES
GPS SETUP
SYS SETUP
SOFT VER.
OTHERS
Main menu
2. Use the
Omnipad
(
) to choose “INST MENU” and then press the
ENT
key.
INSTALLATION SETUP
MOUNTING
:
WALL
DIRECTION :
A
ANT POSITION SETUP
LANGUAGE
: ENG
ROLL OFFSET : 0.0
PITCH OFFSET : 0.0
Installation setup menu
3. “MOUNTING” is selected; press the
ENT
key.
4. Use the
Omnipad
to choose the mounting method: “FLOOR”, “WALL” or
“INVERT” as appropriate.
5. Press the
ENT
key.
6. “DIRECTION” is selected; press the
ENT
key.
7. Use the
Omnipad
to choose mounting direction (“A”, “B”, “C” or “D”) as
appropriate. Refer to paragraph 1.2.
8. Press the
ENT
key.
9. ANT POSITION SETUP is selected; press the
ENT
key.
10. You are asked if it is OK to setup the antenna; press
◄
to choose YES and
then press the
ENT
key to show the ANT POSTION SETUP display.
ANT POSITION SETUP
TIME:
: 0:00:00
ROL INIT OFF: ???.?
°
PIT INIT OFF : ???.?
°
GPS1-GPS2 : ?.??M
GPS2-GPS3 : ?.??M
GPS3-GPS1 : ?.??M
TURN OFF POWER
WHEN YOU CANCEL
Counts time
elapsed
Antenna position setup display
It takes approx. 40 minutes to measure the distances between antennas. If the
measurement is completed satisfactorily, the message “SETUP COMPLETED.
TURN OFF POWER.” appears. If the measurement failed, the message “ANT
POS OR LENGTH IS NOT PROPER.” appears. In this case, adjust antenna
positions referring to the mounting guidelines.