background image

 

 

Cables

:  Make sure to use the correct cables. A chart is provided below, 

for your reference: 

 

Max. Watt Output

 

DC Amps Req’d

 

Wire Gauge

 

150W

 

15A

 

#14

 

300W

 

30A

 

#10

 

600W

 

60A

 

#6 or 2 x #10

 

1000W

 

100A

 

#2 or 2 x #6

 

1500W

 

150A

 

#2 or 2 x #6

 

2200W

 

220A

 

#2 or 2 x #6

 

 

Connection to the battery

 

-Lay the flexible connecting cable (positive) and (negative) from the 
battery to the connecting terminals of the inverter (take cable cross 
section from the table). 

 

 

-Connect first the positive, then the negative cable. 

Make sure the terminals are not reversed! 

Reverse polarity connection will blow the internal fuses. This will void the 
warranty. 

 
 
 
 
 
 
 
 
 
 

 

-Lay the flexible chassis ground cable from the chassis of the vehicle to 
the chassis ground on the rack of the inverter. 
-Connect the chassis ground. 

Summary of Contents for 782-6610

Page 1: ......

Page 2: ...ldren The inverter may not be operated in a damp or wet environment The inverter may not be used in rooms containing flammable materials Make sure the inverter is well ventilated Service and repair may only be carried out by skilled persons who are familiar with the risks involved and the relevant regulations Caution by installation on boats Incorrect installation of electrical units on a boat may...

Page 3: ...the bottom of the inverter and the air outlet on the back side may not be blocked The installation surface must be balanced and sufficiently strong Installation of the inverter Adjust the inverter to the chosen installation place and mark the fixing points Fix the inverter by using the self chosen fixing method Electrical connection General instructions for electrical connection In case of the inv...

Page 4: ...e flexible connecting cable positive and negative from the battery to the connecting terminals of the inverter take cable cross section from the table Connect first the positive then the negative cable Make sure the terminals are not reversed Reverse polarity connection will blow the internal fuses This will void the warranty Lay the flexible chassis ground cable from the chassis of the vehicle to...

Page 5: ...ut voltage OVER TEMP LED Lights Red The inverter has been overheated Switch off the inverter and the device Wait approx 2 minutes and switch on the inverter only Reduce the load and make sure that there is better ventilation for the inverter Then switch on the inverter and the device again Overload LED Current consumption of the device is too high Also there could be a short of the device Switch o...

Page 6: ...V 3 Output Freq 60Hz 60Hz Waveform Pure Sine Pure Sine Total Harmonic Distortion 3 3 Input Voltage Range 10V 15V 10V 15V Efficiency 85 85 No Load Current Draw 0 85A 1 0 amp Low Battery Alarm 10 7V 10 7V Low Battery Shut Down 10V 10V Dimension L x W x H 13 2 x 9 3 x 3 3 in 16 7 x 9 3 x 3 3 in Weight 8 lbs 11 lbs ...

Page 7: ... 115V 3 115V 3 Output Freq 60Hz 60Hz Waveform Pure Sine Pure Sine Total Harmonic Distortion 3 3 Input Voltage Range 10V 15V 10V 15V Efficiency 85 85 No Load Current Draw 1 0 amp 1 0 amp Low Battery Alarm 10 7V 10 7V Low Battery Shut Down 10V 10V Dimension L x W x H 16 3 x 11 2 x 3 9 16 3 x 11 2 x 3 9 Weight 13 8 lbs 17 lbs ...

Page 8: ......

Reviews: