Cables
: Make sure to use the correct cables. A chart is provided below,
for your reference:
Max. Watt Output
DC Amps Req’d
Wire Gauge
150W
15A
#14
300W
30A
#10
600W
60A
#6 or 2 x #10
1000W
100A
#2 or 2 x #6
1500W
150A
#2 or 2 x #6
2200W
220A
#2 or 2 x #6
Connection to the battery
-Lay the flexible connecting cable (positive) and (negative) from the
battery to the connecting terminals of the inverter (take cable cross
section from the table).
-Connect first the positive, then the negative cable.
!
Make sure the terminals are not reversed!
Reverse polarity connection will blow the internal fuses. This will void the
warranty.
-Lay the flexible chassis ground cable from the chassis of the vehicle to
the chassis ground on the rack of the inverter.
-Connect the chassis ground.