background image

 

 

 

  

Installation, Operation and 
Maintenance Manual 
 
 
US Water Oxi-Gen Iron, Sulfur 
and Manganese Eradication 
System 
 

 

Oxi-Gen 150-OXi-2P 
Oxi-Gen 150-OXi-3P 
Oxi-Gen 150-OXi-4P 
Oxi-Gen 150-OXi-5P 
Oxi-Gen 150-OXi-6P 

 

 

US Water Systems, Inc. 

1209 Country Club Road 

Indianapolis, IN 46234 

1-800-608-8792 

info@uswatersystems.com 

www.uswatersystems.com 

Summary of Contents for Oxi-Gen 150-OXi-2P

Page 1: ...on Sulfur and Manganese Eradication System Oxi Gen 150 OXi 2P Oxi Gen 150 OXi 3P Oxi Gen 150 OXi 4P Oxi Gen 150 OXi 5P Oxi Gen 150 OXi 6P US Water Systems Inc 1209 Country Club Road Indianapolis IN 46...

Page 2: ...and Valve Installation 8 Carbon Filter Installation Instructions 9 Carbon Filter Valve Features 10 Carbon Filter Valve Features and Programming 12 Carbon Filter Valve Programming 13 Carbon Filter Sta...

Page 3: ...er of bathrooms 1 Bathroom 5 GPM 2 Bathrooms 8 GPM 3 Bathrooms 10 GPM 4 Bathrooms 12 GPM 5 Bathrooms 15 GPM 6 Bathrooms 20 GPM Hydrogen peroxide or H2O2 is a powerful yet versatile oxidant that is bot...

Page 4: ...e oxidizes the contaminants and the by product is H2O water This is much safer than using chlorine in that chlorine can cause other problems in the water stream such as chloramines and trihalomethanes...

Page 5: ...to assure the accuracy of the dosage The Stenner Proportional Injection System can be utilized to inject any number of chemicals including chlorine hydrogen peroxide polyphosphate Rid O Rust and many...

Page 6: ...5 Secure wall mount bracket to wall studs using the included lag bolts or other suitable hardware Hang panel on to wall mount bracket 6 Glue stubbed cut pipe into slip socket After glue is cured hand...

Page 7: ...4 Slide roof into pump mounting bracket over motor WARNING When pressurizing the system gradually allow water to flow Shocking the meter by over speeding it with high flow rates can damage the interna...

Page 8: ...stem 1 Remove the tank from carton 2 Verify the riser is still fully engaged in the Vortech plate 3 Place a piece of duct tape over the riser tube so no media enters the riser while filling 4 Make sur...

Page 9: ...nimum of 1 2 Backwash flow rates in excess of 7 gpm or length in excess of 20 require 3 4 drain line Commercial drain lines should be the same size as the drain line flow control 4 The inlet on the by...

Page 10: ...by pressing the Extra Cycle button for five seconds The Parameter Display displays the current Cycle Step BW RR etc during backwash and the data display counts down the time remaining for that cycle...

Page 11: ...d backwash time when the number of days since the last backwash equals the backwash day override value Day of the Week Control This control regenerates the system on a weekly schedule The schedule is...

Page 12: ...or do not appear in filter mode Entering Master Programming Mode Set the Time Of Day display to 12 01 P M Press the extra cycle Then press and hold the Up and Down buttons together until the programmi...

Page 13: ...2 in Service C Unit Capacity Unit Capacity Grains H Feedwater Hardness Hardness of Inlet Water RS Reserve Selection Percentage Safety Factor rc Fixed Reserve Capacity SF Safety Factor Percentage of t...

Page 14: ...preferably glass should be full of bubbles immediately after the sample is taken If not the installer will adjust the knob to 50 run the water for 10 15 minutes and check again 4 Continue adjusting th...

Page 15: ...s an indication that the system is being overfed with H2O2 This occurs because after installation the water will become cleaner and the initial dosage of H2O2 may need to be adjusted to compensate for...

Page 16: ...ter Open blow down valve and flush the filter 3 6 Months N A Injection Panel Pump Tube Inspect pump tube and replace as needed 2 Tube 1 5 Years 411 UCCP202 Injection Panel Duck Bill Check Valve Replac...

Page 17: ...17 Flow Schematic Installation Operation and Maintenance Manual Oxi Gen Oxi 2P 3P 4P 5P 6P System...

Page 18: ...ther casualty or if the original serial numbers have been removed Fouling or damage to the resin caused by iron sulfur bacterial iron silt sand tannins or ganics bacteria hot water or chlorine voids t...

Reviews: