1. First Check

 

 

 

You  will  need  an  original  SkyWind  NG  turbine  including  the  automatic  storm  control 
from  FuSystems  SkyWind  GmbH.  If  you  are  not  sure  wether  your  parts  are  original  or 
not stop the installation and contact FuSystems SkyWind. 

 

 

Your SkyWind NG turbine contains:

 

 

-

 Nacelle with generator installed

 

 

-

 2x Patented SkyWind NG all

-

metal rotor blade 

 

 

-

 Grid inverter including

 

 

 

1x SkyWind NG grid inverter with LCD

-

Display

 

 

 

1x Grid connection cable for grid inverter

 

 

 

2x Dump load resistor connection cable

 

 

 

2x Dump load resistor wall mount

 

 

 

1x Dump load resistor

 

 

-

 Automatic storm control including 

 

 

 

1x Wind speed sensor 

 

 

 

1x Turbine cut

-

out relais

 

 

 

1x Storm control unit

 

 

-

 Spray Can Protective Wax Coating

 

 

All parts must be checked for any visual damage. Only new and undamaged parts must 
be installed!

 

 

Only trained professionals with extensive knowledge of the dangers of installation and 
operation may install and handle SkyWind NG turbines and accessories!

 

Page 2 

| SkyWind Installation Handbook

 

Summary of Contents for SkyWind NG

Page 1: ...Micro Wind Turbine Rev 2 0 SkyWind NG Efficient Wind Power The installation must be done by trained professionals only The installer must be qualified and accredited for work on AC electrical installations Expert knowledge and documentation is mandatory ...

Page 2: ...d inverter with LCD Display 1x Grid connection cable for grid inverter 2x Dump load resistor connection cable 2x Dump load resistor wall mount 1x Dump load resistor Automatic storm control including 1x Wind speed sensor 1x Turbine cut out relais 1x Storm control unit Spray Can Protective Wax Coating All parts must be checked for any visual damage Only new and undamaged parts must be installed Only...

Page 3: ...ground at least BASIC RULE The closer a turbine is mounted to the ground the more energy of the airstream will be lost due to ground friction In most cases a turbine installed in 6m height will generate only 30 40 of a turbine mounted at 10m hub height at the same site When installed on a rooftop the hub height should be about 1 3 of the buildings height or width whatever is greater above the buil...

Page 4: ...o not place the turbine on the back This would lead to the metal deforming once the cover is removed Check the turbine for any potential visual damages Check the generator by turning the shaft by hand If needed you may conect the genera tor to a 30 V DC power source The generator should consume about 0 45 A Any visual damage on the turbines packaging must be reported to the shipper immedi atly upo...

Page 5: ...of loss of screws please contact FuSystems SkyWind 5 Nacelle Cable Connection Measure up 6 mm AWG 10 solar cable so that the lengh will be sufficient from turbine to the inverter The DC cable should not be longer than 20 m If a longer distance must be covered change from 6 mm to 12 mm AWG 6 after the first five meters The dis tance covered DC must not exceed 50 m in any case Lead the cable from th...

Page 6: ... of a voltage drop The switch may only be operated every five minutes to allow cool down of the relay Make the necessary DC connections between automatic storm control and inverter See wiring diagram on the next page for details 7 Mounting Preparation Attach a fitting ring terminal to the end of your DC cable to ensure easy and quick connection to the inverter later on If you use more than a singl...

Page 7: ...he turbines limitations The storm control will stop the turbine by short circuiting the turbines DC side For this reason the poles Nr 1 12 and 3 32 must be connected to each other The wind sensor must be installed 0 20m below the rotor discs lowest point on the mast of the wind turbine After installation the system must be checked in two separate ways 1 Shut off the turbines AC power The rotor rot...

Page 8: ...lack connectors la beled with DC INPUT yellow marking Make sure that the polarity is correct Mount the dumpload close to the inverter but not below it In case of too much power the resistor might become very hot Do not mount it onto flammable surfaces and use the mounts delivered with your turbine Connect the dumpload to the connectors labeled DUMPLOAD green marking Page 8 SkyWind Installation Han...

Page 9: ...t da ta field Activate the data set up by pushing the Gear button on the side of the display and select the cor rect number by again using the arrow buttons By pushing the Gear button again you confirm your ent ry Enter the complete power curve After completing the power curve navigate to the Dumpload box by using the arrow buttons and acti vate it using the Gear button Select 45V if you decided f...

Page 10: ...ng screws yellow markings Make sure that both screws are evenly tightened The nacelle must be fixed in an absolutly parallel position to the ground 13 Finalizing The Electrical Installation Check the whole electrical installation and write down your wiring diagram Document all settings of your storm control system and of your inverter by taking pic tures Without photographic documentation your war...

Page 11: ...the manual turbine stop or make sure that the storm control is without power This way the turbine will not start up immediatly after installation of the rotor blade Install the patented SkyWind rotor blade as the last part of the installation The blade is made of one piece and ships balanced for best possible performance After installation of the blade between the two precision made aluminum cones...

Page 12: ...orm as no wind turbine is able to withstand the ext reme forces of such events This document represents the interpretation of the original document Bedienungsanleitung Version 4 0 which may be found online at http myskywind com SkyWind Infothek Flyer Broschuren Vide Bedienungsanleitung SkyWind 4 0 pdf and was made to the best knowledge of the interpreter Only the original document is legally bindi...