Communication port.
Cover
166
Fu
nc
tio
n
Sensor
Sensor Register
This function registers additional sensors. Connect the sensor as shown in the fi gure and
register as follows. The sensor ID is registered in the transmitter.
This function is set when adding one telemetry sensor of the same type.
Connecting S.BUS/S.BUS2
ser vo connector to the
T7PX.
Sensor (The battery is not necessary)
Confi rm sensor connection
1
(Start slot selection)
Tap the [Register], The confi rmation screen will be displayed. To execute, tap [Yes] to hear
an electronic sound and fi nish setting. To cancel, select [No] and touch it. If "Success" ap-
pears on the screen, registration is complete. If registering a sensor that has already been
registered is attempted, the message "Failed; The same sensor has been registered" will be
displayed. If the message "Failed; The connected sensor is not ready." is displayed, check
the sensor connection. If it is securely connected, the sensor or the transmitter may be
faulty.
2
When fi nished, return to the Telemetry screen by pressing the HOME button.
How to change start slot and set empty slot