31
CDR-5000 Functions
MIDDLE STAGE
This shows the estimated average voltage of a battery at a middle stage of discharging process by using
the time consumed for discharging from the beginning to the end.
LAST STAGE
This shows the estimated average voltage of a battery at a late stage of discharging process by using the
time consumed for discharging from the beginning to the end.
INTERNAL RES.
This shows the internal resistance of the battery that is under charging or discharging.
CAPACITY
This shows the accumulated amount of charge or discharge that has been charged or discharged from
the beginning.
TIME
This shows the accumulated amount of time from the start of charging or discharging.
POER LEVEL
This is the number that represents the status of a battery under charging or discharging by calculating
from the voltage drop of the battery to which a certain constant load is applied. The maximum is 120%.
MATCH LEVEL
This shows the matched level among the battery cells how the cells are well matched to each other in
terms of their characteristics.
AVE.BAT.TEMP.
This shows the average temperature of the battery measured by Thermo Sensor or Thermo Stand.