34
CDR-5000 Functions
Graph Screen
Graphs are available for the data of charging or discharging under operation at DX or the data of the
end of the last operation at DX.
Even if the battery is disconnected from the DX port, the data on the screen will not be cleared. But the
data on the screen will be reset by newly connecting a battery.
Switching off CDR-5000 will clear all the data.
<How to operate>
Push "Graph" key in the "DX DATA" screen to move to "GRAPH Screen Page1".
9 types of screens are available and can be selected by using "Graph", " " and " " keys.
[GRAPH Screen Page 1 (CHG V-ºC/Time)]
This graph shows the relationship between the charging time, battery voltage and its temperature.
(Applicable for a battery of 1 to 36 cells) Although no graphs will be shown during discharging, the
graph of the previous charging graph will be shown after charging is completed in cycle mode.
*The messages on the top of the screen are (from left to right):
Graph type or charging current appears alternatively. (while charging)
V: output voltage
B.T: temperature of the battery
The messages on the bottom of the screen are (from left to right):
AVE: an average voltage at charging
C: charged amount
T: time consumed for charging
<How to operate>
A cursor line vertical to the time axis will appear by pushing " " key.
The cursor line can be moved left and right by pushing " " and " " keys.
*The messages at the bottom of the screen will change when the cursor line appears.
From left to right on the bottom of the screen:
D.L. : output voltage
B.T. : battery temperature
T : the time at the crossing point between the cursor and the time axis
D.L. and B.T. are represented by values measured at the time T. In addition, D.L. and B.T. are represented by the
minimum value and maximum value respectively taken at vicinity of the time T. If the minimum value is not equal to
the maximum value, those values will be shown on the screen one after the other.