113
< Linkage menu >
Telemetry Alarm Duration and Repeat time
The repeat time and duration time for the telemetry alarm (buzzer, vibration and speech) can be set.
Duration is not displayed when
Repeat is INH.
Alarm
output
Duration time 5s
Repeat time 8s
OFF
OFF
OFF
ON
ON
ON
e.g. Repeat time is 8 seconds and Duration time is 5 seconds.
žŧƘƕƄƗƌƒƑŃƄƑƇŃŵƈƓƈƄƗŃƗƌƐƈŃƉƒƕŃŷƈƏƈƐƈƗƕƜŃŤƏƄƕƐƀ
ŏ
Tap the [Telemetry Setting] button in the Linkage
menu to call the setup screen shown below.
Duration
It is an alarm output time.
Setting range:1 s 〜 30 s
Initial value:INH
Duration value has to be less than
repeat value.
Duration time is extended when the
other alarm event occurs.
Repeat
It is a repeat time of an alarm
output.
Setting range:INH,1 s 〜 240 s
Initial value:INH