95
< Linkage menu >
Telemetry: Receiver [Battery]
Displaying data from the
receiver battery voltage
In this screen, the battery voltage of a receiver is
displayed.
If it becomes higher or lower than the settin, an
alarm and/or vibration will alert you.
*It cannot be used in FASST mode and S-FHSS mode.
*Only receiver voltage and EXT voltage can be used in
FASSTest12CH mode.
*The FASSTest18CH /T-FHSS mode can use all the telemetry
functions.
Alarm set
1. Tap Alarm and choose from Bu
]]
er, Voice,
and Inhibit.
2. Choose "Inhibit" for Vibrator if not using the
vibrator alarm. If using vibrator, choose one
of the three types.
3. Tap to the Limit [4.0V] item.
4. Adjust the rate using the "
ʈʈ
" "
ʈ
" "
ʆ
" "
ʆʆ
"
buttons.
Initial value: 4.0V
Adjustment
range:
0.0V~100.0V
*When the screen is tapped for one second, the rate is reset
to the initial value.
5. To terminate the input and return to the
original state, push the H/E button.
Receiver battery
voltage
Sets the voltage on
w h i c h t h e a l a r m
operates.
↓ The "down" arrow
will indicate that an
alarm will sound when
the voltage drops to
below the setting.
Alarm is chosen from
Buzzer, Voice, and
Inhibit.
Allows Speech to be
turned ON or OFF.
ŏ
Tap the [Receiver] button in the Telemetry screen
to call the setup screen shown below.
Max. and min. values
s i n c e t h e p o w e r
was turned ON will
display.
Type 1
Type 2
Type 3
"Vibrator" type
If the following types are selected, the transmitter
will vibrate during the warning.
ŏ
Return to
Linkage menu