11
GY520 Link
FUTABA CORPORATION Phone: (043) 296-5118 Facsimile: (043) 296-5124
Makuhari Techno Garden Bldg., B6F 1-3 Nakase, Mihama-ku, Chiba 261-8555, Japan
©FUTABA CORPORATION 2009, 04 (1)
Sets the AVCS operating range. At initial value 300, the servo operating range
becomes about 30°. When the set value is increased, the operating range increases
and the neutral correction range due to cross wind, etc. increases, and tail stop
operation, etc. are affected.
• D gain
Initial value=150 setting range: 0-250
Sets the gyro differential operation gain. The characteristic at tail stopping changes.
• D damping
Initial value=40 setting range=0-100
Sets the gyro differential operation duration time. The characteristic at tail stopping
changes.
• Base Gain
Initial value=50 setting range: 30-100
Sets the gyro control basic gain. When the set value is increased, the gyro gain
decreases. For example, if the set value is changed to 100, the gyro gain is halved. If
the transmitter gain setting is doubled in this state, gain becomes the same as in the
previous state.
• Limit
Initial value: Left=100, Right=100, setting range: 50-150
Sets the servo operating angle limit position. Set after the gyro is mounted to the
fuselage. When the "Enter" button is pressed, the setting mode is entered. Slide
the scale bar in one direction and check the servo operating position and position
it so that the servo horn does not interfere with the linkage. Memorize this position
by pressing the "Set" button. Next, move the scale bar up to the other limit position
and perform the same operation. The limit value cannot be set to 50% or less. After
deciding the limit positions, finally transfer the set value to the GY520 by pressing the
"Write" button.