149
[Corresponding model type]: Airplane/glider general
Acceleration
Setting method
● Acceleration rate setting (Rate)
● The return time after operation (Damping)
can be set.
● The operation point at acceleration
and deceleration can be set. When an
operation point is exceeded, acceleration is
performed.
● Select [Acceleration] at the model
menu and call the setup screen shown
below.
Acceleration setting can be performed at Elevator,
Elevator → Camber and Aileron → Rudder. (Glider
only)
● This setting is divided into elevator setting and camber
setting. The setting method is the same.
● Camber setting sets the acceleration function for Ele
to camber mixing. Setting is not performed when Ele to
camber mixing is INH.
● The acceleration function can be set for both the up
side and down side.
● Function ON/OFF switch setting is performed for
Aileron→ Rudder setting only.
● Aileron→ Rudder setting is acceleration
function setting for Aileron→ Rudder mixing. It is not
performed when Aileron→ Rudder mixing is INH.
Note: When using the acceleration function,
since the servo stroke is large, make your
settings so there is no binding of your linkage.
Operation up to this
range will initiate
acceleration.
Act position
The rate the angle
increases.
To next page
2/3 : Elevator → Camber
3/3 : Aileron → Rudder
The return time after operation (Damping)
can be set.
(First return)1 ~ 100(Slow return)
(Acceleration doesn't function as 0.)
When using this
function, Tap [INH].
(ON is displayed.)
Condition group/
single mode selection
(Gr. /Sngl)
Current position
●Return to Model menu