40
Multicross 5 Super Vision
www.laseto.be
EN
First steps
•
Remove any protective fi lms where applied.
•
Open the battery compartment and insert batteries, please taking care to
observe the indicated polarity.
•
Turn the transportation lock(3) to the "ON" position. The pendulum levelling
mechanism is released, and the instrument is able to align itself on its own. Make
sure that the instrument is not on too much of a slope (within 3°). If the slope of
the instrument should exceed 3°, the lasers will fl ash or will go out automatically.
•
Use the adjustable feet (6) or locate the tripod so that the air-bubble is within the
instrument's levelling range. NB: the accuracy of the instrument depends on the
proper centralisation of the air-bubble. Max. 2 mm/10 m.
Horizontal alignment
•
After disengagement of the pendulum locking system, and provided the
instrument is within its levelling range, the air-bubble is automatically at the
horizontal level.
•
The horizontal line may be activated or deactivated using the "H/V" button).
•
If possible, it is recommended that the horizontal line should be placed at
working height. This will improve the work quality.
•
NB: cross line lasers can only be used on tripods which are adjustable in height,
such as cranked or telescopic tripods.
•
Use the rotating case (4) to position the horizontal line.
•
If the workplace is very brightly lit, e.g. out of doors, it may be necessary to use
the laser receiver.
Multicross_5_Extreme_Vision_New.indd 40
29/01/14 09:53
Summary of Contents for 030.05
Page 2: ...Multicross_5_Extreme_Vision_New indd 2 29 01 14 09 52...
Page 18: ...Multicross_5_Extreme_Vision_New indd 18 29 01 14 09 53...
Page 34: ...Multicross_5_Extreme_Vision_New indd 34 29 01 14 09 53...
Page 50: ...Multicross_5_Extreme_Vision_New indd 50 29 01 14 09 53...
Page 67: ...Multicross 5 SuperVision 67 NOTES Multicross_5_Extreme_Vision_New indd 67 29 01 14 09 53...