MANUAL
250.120RC – DISTY 120RC [EN]
V1.0 – 09.2022
16
ERR 4
Fail of memorizer
Please contact the manufacturer.
ERR 5
Pythagoras measuring error
Please re-measure
ERR 6
Exceed the measuring range
ERR 7
Fail of tilt
Contact the manufacturer.
SPECIFICATIONS
Working range
≤
120 m
Smallest unit displayed
0,001 m
Measurement accuracy
± 0,002 m
Note: use a reflector to increase the measurement
range in case of too much light/poor reflective area.
Laser
Class 2: 635 nm, < 1mW
Continuous distance measuring (tracking)
Yes
Area/Volume/Pythagoras (simple & complex)
Yes
Optional units
m, inch, ft
°, %
Addition/Subtraction of measurements
Yes
Maximum/Minimum values
Yes
Staking-Out
Yes
Delay measurements
Yes
Self-calibration
Yes
Angle of tilt
±90°
Multi-direction electronic level bubble
Yes
Auxiliary sight (camera)
Yes
USB-connector
Yes
Storage temperature range
-20°C < T < 60°C
Working temperature range
0°C < T < 40°C
Batteries
3 x 1,2V AAA NiMH batteries (rechargeable)
or 3 x 1,5V AAA Alkaline batteries
Dimensions
130 x 56 x 29 mm
Weight
0,15 kg
Tripod connector
¼
”
Dust-/waterproofness
IP54
Typical Tolerance: ±2mm, when reflectivity 100% (white surface), environment light <2000
LUX. 25 °C Tolerance is usually affected by the distance, reflectivity, and environment light etc.
It probably gets tolerance around ±( 2mm+0.2mm/m).